im-tek.com

Gestra TRS5-40

Gestra

Product Code: TRS5-40
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra TRS5-40

DescriptionThe control unit TRS 5-40 together with the temperature sensors TRS 5-6x and the temperature transmitter TRV 5-40 constitutes a temperature monitoring system. Two temperature sensors TRG 5-6x detect the temperature values which are then converted by the temperature transmitter TRV 5-40 and made available for the CAN bus in the form of a data telegram. The CANopen protocol is used for the data transfer via CAN bus. The control unit TRS 5-40 can be used ? as MIN and MAX temperature monitor in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x each and ? as temperature controller in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x (MIN or MAX) The control unit TRS 5-40 is also available with two actual value outputs 4 - 20 mA. The equipment combinations can be used for controlling or monitoring temperatures in steam boilers and (pressurised) hot water installations to TRD and EN 12952 and EN 12953.Function The control unit TRS 5-40 evaluates the data telegram coming from the temperature transmitter TRV 5-40 at regular intervals. This data telegram contains: ? Actual value and ajdusted switchpoint for measuring channel 1, ? Actual value and ajdusted switchpoint for measuring channel 2, ? Temperature in the housing of the temperature transmitter. In addition, the following error messages are also included in the data telegram: ? Malfunction in the temperature sensor (sensor damaged, short circuit), ? Temperature in the housing of the temperature transmitter too high, ? Communication error. The output relays 1 – 4 are assigned to the measuring channels 1 and 2 as follows: ? Measuring channel 1: Output relay 1 ? Measuring channel 2: Output relays 2, 3 and 4. To activate or de-activate the measuring channels and to set the functions use the code switch or the operating & display unit URB 2. Use the operating & display unit URB 2 to set the MIN / MAX temperature switchpoints for the temperature control as well as to establish the actual value outputs. If there is an error message relay(s) 1 and/or 4 will be de-energized.

Recommended Products For Gestra


Gestra LRG17-40
Gestra TRG5-53
Gestra BK36A-7
Gestra UNA45MAX
Gestra UNA 45V DN25 PN40 FLANSCH EN PN40 DUPLEX
Gestra WB26
Gestra KS92-1 266154402 Universal Controller
Gestra BA28 Continuous Blowdown Valve
Gestra NGRS 15-1 Compact System for Level Monitoring
Gestra NRG16-38S
Gestra 510 Continuous Blowdown Ball Valve
Gestra MK35/31 1.0460 /A105 3/8
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra NRG 16-50 PN40 G3/4
Gestra BK46
Gestra RK86 CHECK VALVE
Gestra NRG111-50
Gestra UNA46
HFB GOF 236 Plummer Block Housing
Checkline TI-PVX Thickness Gauge With 10mhz Pencil Probe
Gefran LT-M-0550-S L000X000A0N Potentiometer
Grundfos MTR 3-2/2 A-W-A-HUUV Immersible Pump
CD Automation KS33 Solid State Relay
Gefran PC-H-0800 0000X000D0N Potentiometer
Metalwork 6181008U LUB 400 1 CD AUTOMATIC
Gefran WPG-A-E-1250-N 0000X000X00X0XX Magnetostrictives
ETP HYDRO-GRIP B-50/60-240 Sleeve
Gefran LT-B-0360-S 0000X000N0N Potentiometer
Rhomberg 48T101 Timer - ON delay, Interval
Gefran LT-B-0275-S 0000X000A00 Potentiometer
Kadant 995.595/0006 RX Rotary Union
Imtron SIQUAD DC8 Measuring Amplifier
MBS MLW 88 4 28 1 6000 Sanitary Mixflo Multitube
Kadant 995.170/0002 RX Rotary Union
VISHAY BLH U3G2 Precision Force and Weight Measurement Canisters
Wilkerson M43 Series Coalescing Filter
KSB ETN 150-125-315 GC P1CGA5 B Pump
Eurotherm LA172468U500 400A 660V-700V Fuse Tc Series Eurotherm LA172468U500 400A 660V-700V Fuse Tc Series
Spirax Sarco BSA64T PN40 DN25 Metal Bellows Valve
Albrecht ASS/RV 1st valve as control valve Compact Systems
MBS MLW 114 37 12 1 6000 Sanitary Mixflo Multitube
Mahle Pi 47016-010 70304338 Duplex Filter