im-tek.com

Gestra TRS5-40

Gestra

Product Code: TRS5-40
Brand: Gestra



GET OFFER: info@imtek.com.tr

Description for Gestra TRS5-40

DescriptionThe control unit TRS 5-40 together with the temperature sensors TRS 5-6x and the temperature transmitter TRV 5-40 constitutes a temperature monitoring system. Two temperature sensors TRG 5-6x detect the temperature values which are then converted by the temperature transmitter TRV 5-40 and made available for the CAN bus in the form of a data telegram. The CANopen protocol is used for the data transfer via CAN bus. The control unit TRS 5-40 can be used ? as MIN and MAX temperature monitor in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x each and ? as temperature controller in combination with the temperature transmitter TRV 5-40 and with one temperature sensor TRG 5-6x (MIN or MAX) The control unit TRS 5-40 is also available with two actual value outputs 4 - 20 mA. The equipment combinations can be used for controlling or monitoring temperatures in steam boilers and (pressurised) hot water installations to TRD and EN 12952 and EN 12953.Function The control unit TRS 5-40 evaluates the data telegram coming from the temperature transmitter TRV 5-40 at regular intervals. This data telegram contains: ? Actual value and ajdusted switchpoint for measuring channel 1, ? Actual value and ajdusted switchpoint for measuring channel 2, ? Temperature in the housing of the temperature transmitter. In addition, the following error messages are also included in the data telegram: ? Malfunction in the temperature sensor (sensor damaged, short circuit), ? Temperature in the housing of the temperature transmitter too high, ? Communication error. The output relays 1 – 4 are assigned to the measuring channels 1 and 2 as follows: ? Measuring channel 1: Output relay 1 ? Measuring channel 2: Output relays 2, 3 and 4. To activate or de-activate the measuring channels and to set the functions use the code switch or the operating & display unit URB 2. Use the operating & display unit URB 2 to set the MIN / MAX temperature switchpoints for the temperature control as well as to establish the actual value outputs. If there is an error message relay(s) 1 and/or 4 will be de-energized.

Recommended Products For Gestra


Gestra NRR2-51
Gestra SBO21
Gestra KH Steam-Powered Condensate-Return Unit
Gestra NRGS16-1S
Gestra SZ36A
Gestra NGRS 15-1 Compact System for Level Monitoring
Gestra MPA47
Gestra TS36
Gestra NRG19-51
Gestra ZK313DIN
Gestra MK 35/31 3/8
Gestra TRG5-67
Gestra KDS13
Gestra MK45-2
Gestra UNA14P
Gestra RK76
Gestra SRL63A
Gestra RK49
Adalet TN4X6-2416 TN Series - Clamped Door Terminal Enclosures
MBS MLM 219 n 144 12 1 6000 Multiflo Heat Exchanger
KSB MCPK100-065-125 EC NP2 A Pump
Meister FAA-20 Flow Indicator For Liquids
Rotork IQ Multi-turn electric actuator
Sensitron S4008AM Sensor Head
Hengstler AC58/1214ES.71OLB Absolute Encoder
Scherzinger 3030-045-DM-12-6-Exe Stainless Steel Gear Pumps 3030
Knf N 860.3 ANE Vacuum Pump
KWD BOKU-N-B St 10000-16v (x50) - 36 H7 (x40)- KWN 22014 dy Coupling
Fisher Dirty Service (DST) Trim
Scherzinger 4040-710-DM-75-2-Exd Hastelloy (R) Gear Pumps 4040
Bopp Reuther OI200 Oval Wheel Meter
Grundfos MTR 64-7/7-1 A-F-A-HUUV Immersible Pump
Alfa Laval 9612650101 NON-RETURN VALVE LKC-2-ISO- CLAMP-76-EPDM-304
KSB BPI 322/03C+UMAI 150-9/22 2.5 SQMM S.D.( Pump
Aryung ACFS-T-20-BM Coolant filter system
Topworx 7LG-13568DBA - SPDT, End Sensing, UL GP, Green LED, 3-Pin, 316 Stainless Steel, Model 7L BriteLite GO Switch
Bei Sensors Xhs35-50-R1-Ss-12Nb-28V5-Cw-Sm19 Sensor
Eurotherm 2216E/CC/VH/H7/XX/XX/2FM/ENG/XXXXX/XXXXXX Controller Eurotherm 2216E/CC/VH/H7/XX/XX/2FM/ENG/XXXXX/XXXXXX Controller
Gefran LT-M-0275-S 0000X000X00 Potentiometer
Gefran LM-L-A-0800 0000X010X Linear Position Transducer
Hirschmann RT2-TX/FX 2*24 VDC Ethernet Switch
Faulhaber 12/4 16:1 Planetary Gearhead