im-tek.com

Goyen ECS-ACDC12 Control System

Goyen

Product Code: ECS-ACDC12
Brand: Goyen



GET OFFER: info@imtek.com.tr

Description for Goyen ECS-ACDC12 Control System

ECS Control System AC-IN DC-OUT 12-0/PThe ECS Control System is an intelligent controller developed to provide flexible solutions for economical filter life by minimising the costs associated with maintaining and operating modern dust filtration systems. The integrated dP transducer allows the controller to determine exactly when filters require cleaning. This feature ensures the filters are cleaned only when necessary, dramatically extending filter life and lowering emissions, while significantly reducing compressed air use. The ECS base board has 12 solenoid outputs on board. The addition of expansion cards, matched to the AC or DC output of the controller, increases this number to 360 outputs. The ECS may be ordered as the control board only or in an enclosure (polycarbonate).Features & Specifications:DP SUPPORT 0 to 4.5 kPaINPUT VOLTAGE AC: 100/240 V @ 50/60 HzOUTPUT VOLTAGE AC: 100/240 V @ 50/60 Hz (same as input). DC: 24 VMAXIMUM INPUT POWER AC IN, AC OUT Model: 235 W. AC IN, DC OUT Model: 65 WDISCRETE SOLENOID OUTPUTS 12 outputs, expandable up to 360 via 12 output expansion cardsPROTECTION RATING Polycarbonate: IP65 & NEMA 1, 4, 4X, 12 & 13OPERATING TEMPERATURE ?40°C to 60°C (?40°F to 140°F)ON & OFF TIME ON: 30 ms to 1000 ms, OFF: 1 s to 1000 sINPUTS Voltage Free: Fan Stop, Low Header Alarm, Demand/ContinuousOUTPUTS Voltage Free: Coil is Firing, Coil Alarm, High dP. Analogue Output: 4–20 mA dP signalHigh-performance, cost-minimising controller.Expansion cards extend the control up to 360 solenoid outputs.Quick Pulse TechnologyEach AC output can have 10 pilot valves connected in parallel, enabling up to 3600 pilot valves to be supported. Each DC output can have 2 pilot valves connected in parallel between ?40°C to 60°C (?40°F to 140°F), enabling up to 720 pilot valves to be supported.The main PCB only can have 3 DC pilot valves connected in parallel between ?20°C to 60°C (?4°F to 140°F).Low temperature operation ?40°C (?40°F)Automatic pilot valve detectionVoltage-free coil error output and a visual indication on the display showing which pilot valve output has an error, enabling quick fault finding and debugging.Conforms to the requirements of UL, CE, FCC and RCM.

Recommended Products For Goyen


Goyen ECX-ACAC12 Expansion Card
Goyen GYVT57-084 Coil
Goyen 20BAL-CDANA-6027 VALVE
Goyen RCA45FS010 Remote Pilot Operation
Goyen GYG601158-4 Coil
Goyen K0380 (M1131B) Valve Repair Kit
Goyen CA20-TSX/1658 Replacement Top Cover
Goyen 12BW2-EUBNA-6281 Solenoid Valve
Goyen N282 Solenoid Valve Coil
Goyen GYST2-6-ANKN-2452 Coil
Goyen CA45T020 Diaphragm Valve
Goyen IS-ACDC12 Sensor
Goyen K0383 Solenoid Kit
Goyen 3-5V5110-33X Pilot Enclosure
Goyen CA35T000-320 Diaphragm Valve
Goyen CA25T020 Threaded Valve
Goyen 6TDA5/2 INTERFACE SOLENOID VALVES
Goyen RCAC25FS4022 Diaphragm Valve
Micro Detectors BX80S/10-0HAN Area Sensor
Gefran LT-F-0200-S L000X000N0N Potentiometer
Elcis 59A I02 - Series normal
Alfa Laval 9612075328 VALVE LKB-2 DN100 DIN M/NL EPDM 316L
Aignep 231 MALE PLUG
Enerpac PUD1101E Electric Pump
KSB MCPK050-032-250 EC MP2 A Pump
Vulcanic 2119-27 Screw Plug Immersion Heater
Ciat PWB76 Heat Exchanger
Kadant 9940014/0003 SX Rotary Joint
Turbo TL030(N-V-T)M Straight Through Pulse Valve
Gefran LT-F-0360-S L000X000N00 Potentiometer
Alfa Laval 9612628350 LKB-2 DN80 DIN W/W EPDM 304L KIT ACT LKLA Ø85 NC 6MM
Grundfos NK 32-125.1/100 AA1F2AESBAQEFW1 Pump
Adler FA1 DN25 FLAT BODY BALL VALVES
Kelvion GKE 550H Brazed Plate Heat Exchangers
Habasit T80/F A/S TPU Belt
Stauff 4022-PA-SIP-AF-M-W2 Clamp
Micro Detectors BX80S/10-0H9K Area Sensor
Vulcanic 2322-36 Screw Plug Immersion Heater
Alfa Laval 9612628106 VALVE LKB-2 DN100 DIN M/W EPDM 304L KIT HANDLE 1.1 W/2 POS TYPE A
Scheuch zsm 0891 Rotary Valve
Anderson Greenwood M66 Differential Pressure Manifold
T-T Electric DMP 160-4S/M/L DC Motor