Greyline

Product Code: Portaflow PT400
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline Portaflow PT400 Portable Transit Time Flow Meter

Clamp-on Ultrasonic SensorsChoose Small Pipe or Large Pipe SensorsInternal Battery and/or AC PoweredEasy Calibration and Set-upFlow Proportionate Pulse Output4-20mA OutputRecommended for clean fluids like water, glycol, oil and most chemicals. Sensors can be mounted without shutting down flow and there is no obstruction or pressure drop. The ultrasonic signal travels through all common metal and plastic pipe materials. Flow rate and totalizer are displayed continuously along with battery status, signal strength. Press one key to instantly change the units of flow measurement (e.g. from gallons to liters). Real time flow can be displayed in large numeric values or as a graph.Portaflow calibration is easy with the onscreen menu system. Enter the pipe diameter, wall thickness and pipe material, and the PT400 calculates the optimum mounting method and separation distance for the sensors.The Portaflow PT400 ultrasonic sensors clamp on the outside of vertical or horizontal pipes. Select a Sensor pair for the range of pipe sizes you will monitor:'A' Transducers for 0.51" to 4.5" Outside Diameter (13 to 115 mm)*or'B' Transducers for 2” to 39.37” Outside Diameter (50 to 1000 mm)*Calibration parameters can be stored for up to twenty different sites so that operators can recall calibration setups from the Portaflow memory. Use the 5V pulse or 4-20mA output to transmit to external devices like data loggers or recorders.The PT400 includes 'A' or 'B' sensor pairs, stainless steel guiderail and mounting clamps, sensor cables, coupling compound and AC charger with a rugged polypropylene carry case. It operates up to 16 hours from internal batteries and recharges overnight.Contact Greyline Instruments for specific recommendations in your application.PORTABLE ULTRASONIC FLOW METER SPECIFICATIONSSCOPE: This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.GENERAL:Each portable Transit Time flow meter shall have the following design features and engineering specifications:A. PERFORMANCE SPECIFICATIONSHave an accuracy of ±2% of reading in most clean fluid applications. Have repeatability of ±0.5%.Operate on clean liquids in full pipes with less than 2% solids or gas bubbles.Operate on any sonic conducting pipe material such as carbon steel, stainless steel, galvanized steel, mild steel, copper, UPVC, PVDF, glass, brass and including pipes with bonded liners of epoxy, rubber or cement.Operate on AC/DC power. Include an internal NiMH rechargeable battery with capacity for 16 hours continuous battery operation. Recharge and operate with power input of 100-260VAC 50-60Hz.B. ULTRASONIC TRANSDUCERSHave a dual 2 MHz transmitting/receiving, clamp-on transducers.The transducers shall be waterproof and operate continuously at temperatures from -4°F to 275°F (-20°C to 135°C).The transducers shall be designed to install on pipes with inside diameter ranging from 0.51" to 4.5" OD (13 mm to 115 mm).Have a 6 ft (2 m) long cable from the transducers to the electronics.Shall include manufacturer's recommended sensor coupling compound.Shall include stainless steel sensor mounting guiderails with clamps permitting installation and removal of transducers.Shall include a transducer test block to allow the transducers and inter-connecting cables to be functionally checked.C. ELECTRONICSHave a portable, hand-held ABS enclosure plus a padded carrying case containing the flowmeter, sensors and accessories. Total shipping weight shall not exceed 13 lbs (6 kg).Electronics shall be designed for continuous operation at temperatures from 32° to 122°F (0° to 50° C).Have a built-in 16-key programmer with user-friendly calibration menu and language selection including English, French, Spanish, Portuguese, Russian, Norwegian and Dutch.Have a 64 x 240 pixel backlit LCD graphics display indicating positive and negative flow rates and flow totals, calibration menu, signal strength, battery charge status, date and time.Have flow proportional opto-isolated 0/4-20mA output rated to maximum resistive load of 620 ohms. Have a response time of less than 500 ms and sampling resolution of 50 picoseconds.Have adjustable Reynolds number compensation for pipe wall roughness.Have automatic signal strength monitoring and indication.Have a battery status indicator with automatic low battery shut off and battery overcharge protection.D. MANUFACTURERThe instrument shall be a Portaflow PT400-A Portable Ultrasonic Flow Meter by Greyline Instruments Inc., and warranted against defects in materials and workmanship for one year.PORTABLE ULTRASONIC FLOW METER SPECIFICATIONSSCOPE: This specification covers a portable, ultrasonic Transit Time flow meter by Greyline Instruments, Largo, Florida / Long Sault, Ontario. This portable instrument shall provide for non-intrusive flow measurement, indication, totalizing and transmitting of the flow rate in a full pipe.GENERAL:Each portable Transit Time flow meter shall have the following design features and engineering specifications:A. PERFORMANCE SPECIFICATIONSHave an accuracy of ±2% of reading in most clean fluid applications. Have repeatability of ±0.5%.Operate on clean liquids in full pipes with less than 2% solids or gas bubbles.Operate on any sonic conducting pipe material such as carbon steel, stainless steel, galvanized steel, mild steel, copper, UPVC, PVDF, glass, brass and including pipes with bonded liners of epoxy, rubber or cement.Operate on AC/DC power. Include an internal NiMH rechargeable battery with capacity for 16 hours continuous battery operation. Recharge and operate with power input of 100-260VAC 50-60Hz.B. ULTRASONIC TRANSDUCERSHave a dual 2 MHz transmitting/receiving, clamp-on transducers.The transducers shall be waterproof and operate continuously at temperatures from -4°F to 275°F (-20°C to 135°C).The transducers shall be designed to install on pipes with inside diameter ranging from 2" to 39.37" OD (50 mm to 1000 mm).Have a 6 ft (2 m) long cable from the transducers to the electronics.Shall include manufacturer's recommended sensor coupling compound.Shall include stainless steel sensor mounting guiderails with clamps permitting installation and removal of transducers.Shall include a transducer test block to allow the transducers and inter-connecting cables to be functionally checked.C. ELECTRONICSHave a portable, hand-held ABS enclosure plus a padded carrying case containing the flowmeter, sensors and accessories. Total shipping weight shall not exceed 13 lbs (6 kg).Electronics shall be designed for continuous operation at temperatures from 32° to 122°F (0° to 50° C).Have a built-in 16-key programmer with user-friendly calibration menu and language selection including English, French, Spanish, Portuguese, Russian, Norwegian and Dutch.Have a 64 x 240 pixel backlit LCD graphics display indicating positive and negative flow rates and flow totals, calibration menu, signal strength, battery charge status, date and time.Have flow proportional opto-isolated 0/4-20mA output rated to maximum resistive load of 620 ohms. Have a response time of less than 500 ms and sampling resolution of 50 picoseconds.Have adjustable Reynolds number compensation for pipe wall roughness.Have automatic signal strength monitoring and indication.Have a battery status indicator with automatic low battery shut off and battery overcharge protection.D. MANUFACTURERThe instrument shall be a Portaflow PT400-B Portable Ultrasonic Flow Meter by Greyline Instruments Inc., and warranted against defects in materials and workmanship for one year.

Recommended Products For Greyline


Greyline DFM 6.1 Doppler Flow Meter
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline DLT 2.0 Differential Level Transmitter
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline DFS 5.1 Doppler Flow Switch
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline LIT25 Level Indicating Transmitter
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline ISM 5.0 Insertion Magmeter
MBS MLM 168 n 76 12 1 1000 Multiflo Heat Exchanger
Fisher D Series (D138 and D139-D138 and D139) Filler Valves
KSB BPDN 302/08A+UMAH 150-14/23 Pump
Faulhaber 22E 152:1 Planetary Gearhead
Eaton Vickers (Danfoss) 565849 PRV216SO30 Pressure Reducing Valve
Black Bruin BBR 16H Hydraulic Rotator
Gefran PC-H-0200 L000X000X0N Potentiometer
Gefran LT-M-0500-P L000X000B00 Potentiometer
MBS MLD 76 7 20 1 3000 Mixflo Multitube Demontable Heat Exchanger
Parker DF25120QEVPKG121 Duplex Filter
Parker 22PD105QVT1KG161 Duplex Filter
Alfa Laval 9612935970 LKB-2 DN65 DIN M/M EPDM 304L ASSY ACT LKLA Ø85 NC 6MM
Janitza Prophi 52.08.008 Reactive Power Controller
Dynisco MDT 422F-1/2-3.5C-15/46-B171-B173-SIL2 Melt Pressure Transmitters
KSB Amamix C4131/48 UDG Mixer
Gefran LT-M-0350-S 0000X000A0N Potentiometer
American Industrial AA-1060-SP Heat Exchanger
Vulcanic 2219-04 Screw Plug Immersion Heater
Vulcanic 2119-14 Screw Plug Immersion Heater
Dafram 150TM Ball Valve
Kelvion GVH 700M Brazed Plate Heat Exchangers
Ifm PN5001 Electronic pressure monitor; PNP; Connector
Wilkerson R410C-000 - Regulator
Winsmith U2408S56 RD Speed Reducer