im-tek.com

Greyline SFM 6.1 Ultrasonic Slurry Flow Meter

Greyline

Product Code: SFM 6.1
Brand: Greyline



GET OFFER: info@imtek.com.tr

Description for Greyline SFM 6.1 Ultrasonic Slurry Flow Meter

Rugged NEMA4 EnclosureBacklit LCDSimple 5-Key CalibrationPassword Protected4-20mA/05V Output128 MB Data LoggerMODBUS® RTU or HART OptionalNon-contacting flow monitoring specifically designed for limestone slurry, fly ash slurry, gypsum slurry and many othersThe Greyline SFM 6.1 was specifically developed for the slurry applications found in today’s industrial facilities. The SFM 6.1 incorporates more than 30 years of Greyline ultrasonic flow measurement experience.There is no need to shut down your flow or cut into the pipe. The SFM 6.1 sensor mounts on the outside of a variety of pipe materials ½” in diameter or larger. The SFM 6.1 sends an ultrasonic signal into the pipe and measures acoustic reflections off solids and gas bubbles suspended in the slurry. Installation is fast and easy.Easy to InstallEach SFM 6.1 Slurry Flow Meter includes a clamp-on ultrasonic sensor, an adjustable stainless steel mounting clamp and sensor coupling compound. The sensor fits on the outside of any pipe diameter ½" (12.7 mm) or larger. It takes just a few minutes to install. There is no need to shut down flow.Special FeaturesDigital processing system tracks flow signals accurately and auto-zeroes with signal lossNoise suppression circuitry filters “dirty” power and electrical interference from most VFD'sAutomatically converts between measurement units (e.g. gallons or liters)Calibration data and Totalizer values are stored automatically during power interruptionsOutput “simulation” function simplifies calibration of remote devices (e.g. chart recorders or controllers)Self-tunes to Sensor cable lengthSLURRY FLOW METER SPECIFICATIONSSCOPE: This specification covers a non-intrusive, ultrasonic Doppler-type slurry flow meter as manufactured by Greyline Instruments Inc., Largo, Florida / Long Sault, Ontario. The instrument shall provide for velocity or volumetric indicating and transmitting of the flow rate in a full pipe.A. PERFORMANCE SPECIFICATIONSThe flow meter shall operate with a single-head flow sensor mounted externally on any contiguous pipe material that conducts sound including: carbon steel, stainless steel, ductile iron, copper, FRP, PVC, ABS, or cement lined pipe from 1/2" to 180" (12.5 mm to 4.5 m) ID.Measure and indicate flow rates from +0.25 to +40 ft/sec and -0.25 to -40 ft/sec (+0.075 to +12.2 m/sec and -0.075 to -12.2 m/sec) with accuracy of ±2% of reading on liquids with entrained particles or gases of 100 microns or larger and minimum concentrations of 75 ppm.B. TRANSDUCER (FLOW SENSOR)The flow sensor shall be single-head, ultrasonic in a stainless steel housing. It shall be installed on the outside of a pipe without interrupting flow. The sensor shall be capable of continuous operation at temperatures from -40°F to 300°F (-40°C to 150°C), and to withstand accidental submersion pressures to 10 psi. Manufacturer's recommended coupling compound and stainless steel mounting clamp shall be included.Shall include 20 ft (6m) Sensor cable, shielded coaxial pair.Shall be capable of extending sensor cable up to 500 ft (152m) without requirement for operator adjustment.Shall be transformer isolated and designed to meet intrinsic safe requirements. Shall be designed for maximum RFI rejection, and include automatic high voltage bleeds for nearby lightning strikes.Sensor shall be rated Non-incendive for Class I, Division 2, Groups A, B, C & D locations. C. TRANSMITTERThe transmitter indicator shall be housed in a NEMA4 stainless steel with window and suitable for wall mounting.Flow meter electronics shall be designed to operate at temperatures from -5°F to 140°F (-20°C to 60°C). Electronic circuits are interchangeable with other flow meters having the same model number. The transmitter circuit and calibration frequency standard shall be crystal controlled. The transmitter shall be powered by 100-240VAC 50/60Hz requiring less than 5 Watts.The transmitter shall include a built-in 5-Key calibration system with operator selection of parameters through visual prompts from a Menu calibration system. Systems requiring calibration by Parameter codes or external calibrators shall not be accepted.The 4-20mA shall be flow proportional and isolated, with programmable zero and full scale offsets. Maximum resistive load shall be 1000 ohms. It shall include automatic high voltage bleeds for nearby lightning strikes.Shall include noise suppression circuitry to filter electrical interference.Have a white, backlit matrix LCD display indicating flow rate in user-selected engineering units, units of calibration, relay states, signal strength and 16-digit totalizer.Have 2 control relays rated 5 ampere SPDT. Relays shall be programmable for flow proportional pulse output, or as flow rate alarms with separate ON/OFF set points.Shall display and totalize forward and reverse flow.Electronics shall be modular and field replaceable by means of plug-in circuit boards. The instrument shall detect and load software menus automatically for field-installed options. D. ADDITIONAL FEATURES FOR INSERTION IN SPECIFICATION AS REQUIRED:Sensor shall be rated intrinsically safe to Class I, Groups C,D; Class II, Groups E,F,G; Class III with Intrinsic Safety Barriers.Sensor cable shall be 50 ft (15m) length shielded coaxial pair.Sensor cable shall be 100 ft (30 m) length shielded coaxial pair.Have a Sensor Cable Junction Box and up to 500 ft (152m) length total shielded coaxial pair cable installed in conduit for mechanical protection.Have a thermostatically controlled AC-powered enclosure heater for condensation protection in locations with temperature below -5°F (-20°C).Have power input of 9-32VDC.Have a built-in 2 million point Data Logger with USB output to flash drive or mass storage device. Include Windows software. E. MANUFACTURERThe instrument shall be a Model SFM 6.1 Slurry Flow Meter as manufactured by Greyline Instruments Inc., and warranted against defects in materials and workmanship for one year.

Recommended Products For Greyline


Greyline Portaflow PT400 Portable Transit Time Flow Meter
Greyline DFS 5.1 Doppler Flow Switch
Greyline Stingray 2.0 Portable Level-Velocity Logger
Greyline PTFM 1.0 Portable Transit Time Flow Meter
Greyline DLT 2.0 Differential Level Transmitter
Greyline ISM 5.0 Insertion Magmeter
Greyline TTFM 6.1 Transit Time Flow Meter
Greyline AVFM 6.1 Area-Velocity Flow Meter
Greyline PSL 5.0 Hybrid Pump Station Level Controller
Greyline LIT25 Level Indicating Transmitter
Greyline Pulsar SF2 & Viper Sludge Blanket Detection Bundle
Greyline DFM 6.1 Doppler Flow Meter
Greyline OCF 5.0 Open Channel Flow Monitor
Greyline MantaRay Portable Area-Velocity Flow Meter
Greyline PDFM 5.1 Portable Doppler Flow Meter
Greyline SFM 6.1 Ultrasonic Slurry Flow Meter
Greyline SLT 5.0 Ultrasonic Level & Flow Monitor
Felm F3X 315XD-2 Motor
Alfa Laval 9611444925 BUTTERFLY VALVE LKB ISO CL/CL 51 EPDM 304L
Gefran PC-B-0130 0000X000X00 Potentiometer
Appoldt RM11-1W-1176 Relay Coupler
Eaton Vickers (Danfoss) 507848 Coil
Elma EMC Shielded Flat Front Panels
Indexator 5212475 GV 12S LS Rotator
Greisinger GE151-BNC pH Electrode
Grundfos NK 65-180/124 AA1F1S3ESBQQEKW1 Pump
Nuovafima 6.TB8.9.9.E.---.ATF2.43M.6.C40.T32 (381mm) Thermometer
Alfa Laval 9613403778 LKB-2 DN65 DIN M/M FPM 316L KIT ACT LKLA-T Ø85 NC 6MM
KSB BPD242/04A+UMAI 150E-3/22 1.5 SQMM DOL Pump
Gefran LT-B-1200-S L000X000B0N Potentiometer
Gestra SZ36A
KSB MCPK080-050-125 GG NP2 A Pump
Hengstler RI58-O/10000AK.72RA-F0 Encoder
Eaton DU101-0279 Duplex Filter
Aron AD3O03CZ002 Cetop 3 Pilot Operated Valve A & B to T
Scherzinger 3040-110-DM-37-4 Hastelloy (R) Gear Pumps 3040
Benzlers E Series Industrial Reducer EON & EOS
Hengstler RI59-O/60EQ.7AKB-F0 Encoder
Stenflex Type AS-1 DN 150 Expansion Joint
Rotork manPOWER high-integrity fail-safe valve operation
Foxboro 244LD-KI3R2RNMH1C4-MY Intelligent Buoyancy Transmitter w/Torque Tube