Specifications
LB 382 up to ML 3 040 mm
Measuring standard
Coefficient of linear expansion
Rustproof steel scale tape with AURODUR graduation, grating period 40 µm
?therm 10 x 10–6 K–1
Accuracy grade
±5 µm
Measuring length ML* in mm
Single-section housing
440 640 840 1040 1240 1440 1640 1840 2040 2240 2440 2640 2840 3040
Reference mark* LB 382
LB 382 C
Selectable by selector plate every 50 mm, standard setting: 1 reference mark in the center
Distance-coded
Interface
? 1 VPP
Signal period
40 µm
Diagnostics interface
Analog
Cutoff frequency –3 dB
? 250 kHz
Electrical connection
Separate adapter cable (1 m/3 m/6 m/9 m) connectible to mounting block
Cable length1)
? 150 m
Voltage supply
without load
DC 5 V ±0.25 V/< 150 mA
Traversing speed
? 120 m/min (max. acceleration in measuring direction ? 60 m/s2)
Required moving force
? 15 N
Vibration 55 Hz to 2000 Hz
Shock 11 ms
? 300 m/s2 (EN 60 068-2-6)
? 300 m/s2 (EN 60 068-2-27)
Operating temperature
0 °C to 50 °C
Protection EN 60 529
IP53 when mounted according to the instructions and mounting information
IP64 if compressed air is connected via DA 400
Mass
1.3 kg + 3.6 kg/m measuring length
* Please select when ordering
1) With HEIDENHAIN cable