Scale
LIC 4009
Measuring standard
Coefficient of linear expansion
Steel scale tape with absolute and incremental METALLUR track
?therm 10 · 10–6 K–1
Accuracy grade*
±3 µm, ±15 µm1)
Baseline error
? ±0.750 µm/50 mm (typical)
Measuring length (ML)*
in mm
70 120 170 220 270 320 370 420 520 620 720 820 920 1020
Mass
31 g/m
Scanning head
LIC 411
LIC 419 F
LIC 419 M
LIC 419 P
LIC 419 Y
Interface
EnDat 2.2
Fanuc Serial Interface ?i
Mitsubishi high speed interface
Panasonic Serial Interface
Yaskawa Serial Interface
Ordering designation*
EnDat22
Fanuc05
Mit03-4
Mit02-2
Pana01
YEC07
Measuring step*
0.01 µm (10 nm)
0.005 µm (5 nm)
0.001 µm (1 nm)2)
Calculation time tcal
Clock frequency
? 5 µs
? 16 MHz
–
Traversing speed3)
? 600 m/min
Interpolation error
±20 nm
Electrical connection*
Cable, 1 m or 3 m, with 8-pin M12 coupling (male) or 15-pin D-sub connector (male)
Cable length (with HEIDENHAIN cable)
? 100 m4)
? 50 m
? 30 m
? 50 m
Supply voltage
DC 3.6 V to 14 V
Power consumption3) (max.)
At 3.6 V: ? 700 mW
At 14 V: ? 800 mW
At 3.6 V: ? 850 mW
At 14 V: ? 950 mW
Current consumption (typical)
At 5 V: 75 mA
(without load)
At 5 V: 95 mA (without load)
Vibration 55 Hz to 2000 Hz
Shock 6 ms
? 500 m/s2 (EN 60068-2-6)
? 1000 m/s2 (EN 60068-2-27)
Operating temperature
–10 °C to 70 °C
Mass Scanning head
Connecting cable
Connecting element
? 18 g (without cable)
20 g/m
M12 coupling: 15 g; D-sub connector: 32 g
* Please select when ordering
1) ±5 µm after linear length-error compensation in the evaluation electronics
2) Mitsubishi: measuring length ? 2040 mm
Yaskawa: measuring length ? 1840 mm
3) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure
4) With LIC 411 FS scanning head: clock frequency: 8 MHz