HEIDENHAIN LIP 608 Exposed Linear Encoder


HEIDENHAIN LIP 608  Exposed Linear Encoder Image

Are you interested in the product HEIDENHAIN LIP 608 Exposed Linear Encoder from manufacturer HEIDENHAIN with code LIP 608? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for HEIDENHAIN LIP 608 Exposed Linear Encoder from our live support team now!

ScaleLIP 6001Measuring standard*Coefficient of linear expansionOPTODUR phase grating on Zerodur glass ceramic or glass; grating period: 8 µm?therm = (0 ±0.1) · 10–6 K–1 (Zerodur glass ceramic); ?therm ? 8 · 10–6 K–1 (glass)Accuracy grade*±1 µm (only for Zerodur glass ceramic of up to a measuring length of 1020 mm); ±3 µmBaseline error? ±0.175 µm/5 mmMeasuring length (ML)*in mm 20 30 50 70 120 170 220 270 320 370 420 470 520 570 620 670 720 770 820 870 920 970 1020 1140 1240 1340 1440 1540 1640 1840 2040 2240 2640 2840 3040Reference markOne at midpoint of measuring lengthMass1.1 g + 0.11 g/mm measuring lengthScanning headLIP 608LIP 607Interface  1 VPPTTL1) Integrated interpolation* signal period–4 µm5-fold0.8 µm10-fold0.4 µm25-fold0.16 µm50-fold0.08 µm100-fold0.04 µm500-fold0.008 µmCutoff frequency –3 dB? 1 MHzScanning frequency–––? 312.5 kHz–? 312.5 kHz? 156.25 kHz? 250 kHz? 125 kHz? 62.5 kHz? 125 kHz? 62.5 kHz? 31.25 kHz? 62.5 kHz? 31.25 kHz? 15.63 kHz? 12.5 kHz? 6.25 kHz? 3.13 kHzEdge separation a–––? 0.135 µs–? 0.07 µs? 0.135 µs? 0.03 µs? 0.07 µs? 0.135 µsTraversing speed2)? 240 m/min--–? 75 m/min–? 75 m/min? 37 m/min? 60 m/min? 30 m/min? 15 m/min? 30 m/min? 15 m/min? 7.5 m/min? 15 m/min? 7.5 m/min? 3.7 m/min? 3 m/min? 1.5 m/min? 0.75 m/minInterpolation errorRMS position noise±4 nm 0.4 nm (1 MHZ3))–Electrical connection*Cable outlet on the left/right and straight/angled1 VPP: Cable, 0.5 m/1 m/3 m, with 15-pin D-sub connector (male)TTL: Cable, 0.5 m or 1 m, with interface electronics in the 15-pin D-sub connector (male)Cable lengthWith HEIDENHAIN cable: homing, limit: ? 10 m; only incremental: ? 20 m; during signal adjustment with the PWM 21: ? 3 m Supply voltageDC 5 V ±0.5 VCurrent consumption? 150 mA ? 300 mA (without load)Vibration 55 Hz to 2000 HzShock 6 ms? 500 m/s2 (IEC 60 068-2-6)? 1000 m/s2 (IEC 60 068-2-27)Operating temperature–10 °C to 70 °CMassScanning headConnectorConnecting cable? 5 g (without cable)AK LIP 608 ? 71 g; AK LIP 607 ? 74 g? 24 g/m* Please select when ordering; for measuring lengths < 70 mm, the 'adhesively bonded” mounting type is recommended1) Unclocked TTLx1 possible upon request 2) With TTL: maximum traversing speed during referencing: 16.8 m/min (70 kHz)3) –3dB cutoff frequency of the subsequent electronics