Measuring standard
DIADUR graduation on glass disk
Measuring method
absolute (singleturn)
System accuracy
± 5"
Maximum position error per signal period
± 0.4"
Mechanical device version
Solid shaft for separate shaft coupling
Shaft type
Solid shaft
Shaft diameter
10 mm
Flange version
Rectangular flange with 80 mm centering collar, aluminum
Interface
Fanuc Serial Interface - ?i Interface (incl. ? Interface)
Ordering designation
Fanuc05
Positions per revolution
67108864 (26 bit)
Electrical permissible speed
? 3000 min?¹
Clock frequency
Specific to interfaces
Calculation time tcal
no specified value
Incremental signals
without
Output signals per revolution
16384
Cutoff frequency (-3 dB)
no specified value
Permissible cable length (with HEIDENHAIN cable)
? 50 m
Power supply
DC 3.6 V ... 14 V
Typical current consumption without load
? 140 mA at 5 V
Power consumption
? 1.1 W at 3.6 V
? 1.3 W at 14 V
Connecting direction
Cable outlet for axial and radial use
Cable type
PUR Ø 6.0 mm
Cable length
1 m
Electrical connection
Coupling M12, male, 8-pin
Mechanical permissible speed
? 3000 min?¹
Starting torque at 20 °C
0.02 Nm
Moment of inertia of the rotor (shaft)
0.000050 kgm²
Shaft load
axial 30 N
radial 30 N at shaft end
Vibration 55 Hz to 2000 Hz (EN 60068-2-6)
? 200 m/s²
Shock 6 ms (EN 60068-2-27)
? 1000 m/s²
Maximum operating temperature
? +60 °C
Minimum operating temperature
? -20 °C
Degree of protection
IP 64 (EN 60529)
Mass
kg