Measuring standard
DIADUR graduation on glass disk
Measuring method
incremental
System accuracy
± 2"
Maximum position error per signal period
± 0.7"
Mechanical device version
Hollow shaft with integrated stator coupling
Shaft type
Hollow through shaft
Shaft diameter
60 mm
Flange version
Flange with 200 mm outside diameter and 180 mm centering collar, drainage channels, aluminum
Interface
1 Vpp
Cutoff frequency (-3 dB)
? 180 kHz
Reference mark
one
Line count
18000
Incremental signals
1 Vpp
Power supply
DC 5 V (±10 %)
Total current without load
? 150 mA
Connecting direction
Cable outlet for axial and radial use
Cable type
PUR Ø 6.0 mm
Cable length
1 m
Electrical connection
Coupling M23, male, 12-pin
Permissible cable length (with HEIDENHAIN cable)
? 150 m
Mechanical permissible speed
? 1000 min?¹
Starting torque at 20 °C
? 0.5 Nm
Moment of inertia of the rotor (shaft)
0.0012 kgm²
Permissible axial motion of measured shaft
± 0.1 mm
Natural frequency
? 1000 Hz
Vibration 55 Hz to 2000 Hz (EN 60068-2-6)
? 100 m/s²
Shock 6 ms (EN 60068-2-27)
? 1000 m/s²
Maximum operating temperature
? +50 °C
Minimum operating temperature
? 0 °C
Degree of protection
IP 64 (EN 60529)
Mass