Measuring standard
DIADUR graduation on glass disk
Measuring method
incremental
System accuracy
± 0.4"
Maximum position error per signal period
± 0.3"
Mechanical device version
Blind hollow shaft with integrated stator coupling
Shaft type
Blind hole
Shaft diameter
15 mm
Flange version
Flange with 170 mm outside diameter and 140 mm centering collar, steel 1.4104
Interface
11 µApp
Output signals per revolution
36000
Cutoff frequency (-3 dB)
? 40 kHz
Reference mark
one
Incremental signals
11 µApp
Power supply
DC 5 V (±5 %)
Total current without load
? 250 mA
Connecting direction
Cable outlet for axial and radial use
Cable type
PUR Ø 8.0 mm
Cable length
1 m
Electrical connection
Connector M23, male, 9-pin
Permissible cable length (with HEIDENHAIN cable)
? 15 m
Mechanical permissible speed
? 100 min?¹
Starting torque at 20 °C
? 0.05 Nm
Moment of inertia of the rotor (shaft)
0.0003450 kgm²
Permissible axial motion of measured shaft
± 0.2 mm
Natural frequency
? 350 Hz
Vibration 55 Hz to 2000 Hz (EN 60068-2-6)
? 50 m/s²
Shock 6 ms (EN 60068-2-27)
? 1000 m/s²
Maximum operating temperature
? +30 °C
Minimum operating temperature
? +10 °C
Degree of protection
IP 64 (EN 60529)
Mass
4.0 kg