Scanning head
AK ERO 6180
Interface
1 VPP
Reference mark signal
Square-wave pulse
Cutoff frequency –3 dB
? 200 kHz
Electrical connection
Cable 3 m with D-sub connector (male), 15-pin
Cable length
? 30 m
Voltage supply
DC 5 V ±0.25 V
Current consumption
< 100 mA (without load)
Vibration 55 to 2000 Hz
Shock 6 ms
? 200 m/s2 (EN 60 068-2-6)
? 500 m/s2 (EN 60 068-2-27)
Operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Mass Scanning head
Connector
Cable
? 6 g (without cable)
? 32 g
? 22 g/m
Circular scale
TKN ERO 6100
Measuring standard
Chrome graduation on glass
Signal periods
4096
Accuracy of graduation
±10”
Interpolation error per signal period1)
±5”
Reference marks
One
Hub inside diameter
41 mm
Circular scale outside diameter
70 mm
Mech. permissible speed
? 3500 rpm
Moment of inertia
50 x 10–6 kgm2
Permissible axial motion
? 0.1 mm
Protection EN 60 529
Complete encoder in mounted position: IP00
Mass
? 71 g
1) Interpolation error within one signal period and the accuracy of the graduation together result in the encoder-specific error; for additional error from mounting and bearing of the measured shaft, see Measuring accuracy