Gestra OR52-6

Technical Documentation

Schede Tecniche / Documentazione Prodotto

WhatsApp
Marca
Gestra logo - Official brand
CategoriaAltri
Nome prodottoGestra OR52-6
Codice prodottoNon specificato
Visa – Secure credit card payment acceptedMastercard – Secure credit card payment acceptedAmerican Express – Secure credit card payment acceptedDiners Club – Secure credit card payment acceptedDiscover – Secure credit card payment accepted

Contattaci! 24 ore lavorative (esclusi weekend e festivi) per confermare disponibilità e tempi di consegna.

Descrizione del prodotto

I prodotti Gestra, incluso Gestra OR52-6, vengono approvvigionati tramite canali di importazione parallela e consegnati ai nostri clienti in United States con rapidità e affidabilità. Imtek Engineering offre componenti originali Gestra a prezzi competitivi. Anche se Gestra OR52-6 non è elencato sul nostro sito, è possibile richiedere un preventivo in qualsiasi momento — il nostro team risponderà tempestivamente.

Oil and Turbidity Detector TURBISCOPE OR52-6
Data sheet 810741-08 Issue: 09-2024
Oil and Turbidity Detector TURBISCOPE®
OR 52-5, OR 52-6
Measuring sensors ORG 12 and ORG 22
ppm
OIL OIL
cal
sec
0
1
P
Measuring sensors ORG 12 and ORG 22 Operating pressure
PN 10, 10 bar at max. 160°C Mechanical connections
DN 10, connections G 3/8 A, ISO 228-1 Flowrate 0.5 – 50 l/min Pressure drop
5 [mbar] 1) Fluids water, condensate, drinks, etc.
Max. pH value of the fluid 2) 10.5 Fluid temperature ranges 0°C – 60°C (with drying cartridge)
60°C – 160°C (with vent nipple) Ambient temperature 0 – 60°C Weight approx. 6.8 kg
Materials Housing 0.6025 galvanised Cover
ORG 12: 0.6025 galvanised
ORG 22: 1.4571 Wetted parts
ORG 12: 0.6025 galvanised
ORG 22: 1.4580 Ball valves
ORG 12: 1.4436
ORG 22: 1.4436 Screwed unions
ORG 12: Steel
ORG 22: 1.4571 Glass cylinder Duran 50 Gaskets FFKM Cleaning disc EPDM Light emitter
Bulb 12 V / 10 W BA 15s Protection IP 65 Light receiver 2 silicon photo-electric cells
Protection IP 65
Typical applications ■
In steam boiler and hot-water plants, the oil and turbidity detector can monitor any ingress of oil or grease
into the condensate, the feedwater or the water circuit (EN 12952-7, EN 12953-6). 2 detectors are required for
72 hrs operation.

In addition, the oil & turbidity detector is suitable for monitoring untreated and treated water (gravel filters,
full demineralisation systems, reverse osmosis systems) as well as waste water.

In the food sector, the oil and turbidity detector is used in the brewing and beverage industry (filtration, monitoring
of flavouring, quality assurance, etc.) and for monitoring filtration in the production of cooking oil.
0
ALARM ALARM 1
Technical Data
Use oil and turbidity detector OR 52 for monitoring transparent liquids to detect any ingress of light-scattering and insoluble
foreign matter.
The OR 52-5/-6 oil and turbidity detector consists of a type
ORG 12 or ORG 22 measuring sensor and type ORT 6 measuring transducer that acts as an operating and display unit.
The correct measuring sensor is selected depending on the fluid used.
The oil & turbidity detector is used to detect impurities in transparent liquids. It is chiefly employed in industry and
the food sector, in which high levels of reliability and ease of maintenance are essential.
cal
ppm sec
ORT 6
System description
2
2
E Test Test
Function
Measuring transducer ORT 6
The measuring sensor is a photometric measuring device.
It consists of a light source (light emitter) and two photoelectric cells that make up a light receiver. A constantly
maintained beam of light shines through the transparent liquid. Undissolved foreign particles scatter the beam, which
is measured using the 15° forward-scattered light principle. This scattered light is then converted into an electrical
current and analysed to determine the content of foreign matter.
The measuring transducer is the operating and display unit for actuating the measuring sensor and
analysing the signals. It visually displays the measurement results and is used to set the measuring equipment. It displays the actual value, the triggering of
ALARM 1 and ALARM 2 limit value alarms and malfunctions in the measuring sensor. Limit values are set and displayed
on the measuring transducer.
Use in potentially explosive atmospheres Do not use the equipment in potentially explosive atmospheres.
1) 2)
At a flowrate of 2 l/min and a V-shaped flow through the sensor with a pipe
length of 1 m (DN 10), 4 bends and ζ = 6.1.
A pH value of > 10.5 may cause the glass to suffer wear, depending on temperature.

Domande Frequenti