Kirchgaesser
Kirchgaesser MID-EX-E Electromagnetic Small Flow Meter
Product Code:MID-EX-E
Description
Measuring principle:Electromagnetic (flow)Thinfilm sensor (pressure)Flow measuring ranges:0...10 l/min to 0...600 l/minPressure measuring ranges:0...40 bar (0...4 MPa) bis 0...400 bar (0...40 MPa)Nominal widths:DN10, DN19 and DN25Optional with plug couplers DN10, DN12, DN19, DN25 or DN31Optional with socket nipples DN32 and DN50 (type SSKV heavy version)Nominal pressure ranges:100 bar (10 MPa) to 500 bar (50 MPa)Electrical connection:Terminals and cable gland M25x1.5Machaczek connector type ME2A10PROMOS connector type BN4160Souriau connector series 845, size 1 or 2Hydrostar connector type SKK24Hydrostar connector type SKK45MHirschmann connector type G4A5MOutput signal:Frequency 5...15 HzCurrent 4...20 mAVoltage 1...10 VLimit (switching output)Housing:Sensor: brass or bronzeElectronic: plastic or brassElectrode material:1.4571 (316Ti)Power supply:8.0...13.5 VDC
(11.0 - 13.5 VDC on devices with voltage output and no external power supply)Power consumption:< 1 WPower supply for voltage output:11.0...13.5 VDCProtection acc. to EN 60529:IP 65
Acc. to EN 60068-2-27:Excitation mode: shock half – sineShock duration: 18 msShock amplitude: 30 gNo. of shocks: 3 per directionTest directions: 6 directions in space (± X, ± Y, ± Z)Total no. of shocks: 18Test temperature: room temperatureMarking acc. to 2014/34/EU (ATEX):I M2 Ex ia I Mb (BVS 07 ATEX E 060)Marking acc. to IECEx:Ex ia I Mb (IECEx BVS 07.0010, Dekra EXAM, Germany)Ex ia I (IECEx TSA 11.0043X, TestSafe, WorkCover NSW, Australia)MA safety certificate:
0...80 °CCertificated acc. to IECEx:
0...60 °CProcess temperature:0...100 °CMeasuring uncertainty:Max. ± 2 % of end value, typ. ± 1 %Functional safety:PL d (acc. to EN 13849-1)SIL 2 (acc. to EN 61508)
(11.0 - 13.5 VDC on devices with voltage output and no external power supply)Power consumption:< 1 WPower supply for voltage output:11.0...13.5 VDCProtection acc. to EN 60529:IP 65
Vibration resistance -
Endurance stress with sliding
frequency acc. to EN 60068-2-6:
Acc. to EN 60068-2-27:Excitation mode: shock half – sineShock duration: 18 msShock amplitude: 30 gNo. of shocks: 3 per directionTest directions: 6 directions in space (± X, ± Y, ± Z)Total no. of shocks: 18Test temperature: room temperatureMarking acc. to 2014/34/EU (ATEX):I M2 Ex ia I Mb (BVS 07 ATEX E 060)Marking acc. to IECEx:Ex ia I Mb (IECEx BVS 07.0010, Dekra EXAM, Germany)Ex ia I (IECEx TSA 11.0043X, TestSafe, WorkCover NSW, Australia)MA safety certificate:
J2013333, valid for
MID-EX-ES010LY000A1G55A-050MID-EX-EP019NY160B1J65B-160Ambient temperature:Certificated acc. to ATEX:0...80 °CCertificated acc. to IECEx:
0...60 °CProcess temperature:0...100 °CMeasuring uncertainty:Max. ± 2 % of end value, typ. ± 1 %Functional safety:PL d (acc. to EN 13849-1)SIL 2 (acc. to EN 61508)
Technical Specifications
| Measuring principle: |
|
| Flow measuring ranges: | 0...10 l/min to 0...600 l/min |
| Pressure measuring ranges: | 0...40 bar (0...4 MPa) bis 0...400 bar (0...40 MPa) |
| Nominal widths: |
|
| Nominal pressure ranges: | 100 bar (10 MPa) to 500 bar (50 MPa) |
| Electrical connection: |
|
| Output signal: |
|
| Housing: |
|
| Electrode material: | 1.4571 (316Ti) |
| Power supply: | 8.0...13.5 VDC (11.0 - 13.5 VDC on devices with voltage output and no external power supply) |
| Power consumption: | < 1 W |
| Power supply for voltage output: | 11.0...13.5 VDC |
| Protection acc. to EN 60529: | IP 65 |
Vibration resistance - |
|
| Shock resistance - Acc. to EN 60068-2-27: |
|
| Marking acc. to 2014/34/EU (ATEX): | I M2 Ex ia I Mb (BVS 07 ATEX E 060) |
| Marking acc. to IECEx: |
|
| MA safety certificate: | J2013333, valid for
|
| Ambient temperature: |
|
| Process temperature: | 0...100 °C |
| Measuring uncertainty: | Max. ± 2 % of end value, typ. ± 1 % |
| Functional safety: |
|