JUMO MIDAS DP10 - OEM Differential Pressure Transmitter (401050)


JUMO   MIDAS DP10 - OEM Differential Pressure Transmitter (401050) Image

JUMO MIDAS DP10 - OEM Differential Pressure Transmitter (401050)


Product Name: JUMO MIDAS DP10 - OEM Differential Pressure Transmitter (401050)
Brand: JUMO
Product Code:
Tags: JUMO
MIDAS DP10 - OEM Differential Pressure Transmitter (401050)



Are you interested in the product JUMO MIDAS DP10 - OEM Differential Pressure Transmitter (401050) from manufacturer JUMO with code ? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for JUMO MIDAS DP10 - OEM Differential Pressure Transmitter (401050) from our live support team now!

FeaturesMeasuring ranges: 0 to 400 mbar – 0 to 16 bar differential pressure, silicon sensor with stainless steel separating diaphragmMedium: gaseous, liquid, or low-aggressionVersion with elastomer seal, optional weldingCompact design: as of 78 mm in lengthParts in contact with media: PBT plastic, option with full stainless steelOverload pressure up to 30 bar on one side Tested according to DIN EN 61373 category 1B as well as further relevant railway standards such as DIN EN 50155Customer benefitsEconomicalType 401050 is the differential pressure model in the JUMO MIDAS pressure transmitter range with sensor technology that has been proven thousands of times over. An almost fully automated production sequence (digital compensation and calibration of the sensor module) and a functional design reduce both the production time and manufacturing costs. Process reliabilityThe high quality of every pressure transmitter is ensured by the full final inspection within the completely-automatic measuring and calibration facility. VersatileHigh-quality materials allow for a wide application field. Various output signals, different process connections, and housing materials are available.ApplicationsFilter monitoringA typical application is filter monitoring in gases or liquids, which uses the different pressure ratios before and after the filter to ascertain its pollution.LevelIn pressurized boilers, a differential pressure measurement can be used to determine the exact level, irrespective of system pressure fluctuations.Pump controlThe rotational speed of a pump can be adapted to the requirements of capacity and energy consumption via a control system by measuring the pressure ratio before and after the pump.