Kirchgaesser
Kirchgaesser MID-EX-GL Electromagnetic Large Flow Meter
Product Code:MID-EX-GL
Description
Measuring principle:ElectromagneticFlow measuring ranges:0...100 l/min (DN50) to 0...1000 l/min (DN150) and
0...10 m³/h (DN50) to 0...2000 m³/h (DN300) respectivelyNominal widths:DN50 to DN300 (optional with high pressure couplings, like SSKV heavy version)Nominal pressure ranges:10 bar (1 MPa) to 500 bar (50 MPa)Electrical connection:Terminals and cable glandPROMOS connector type BN4160Machaczek connector type ME2A10Souriau connector type 845, size 1 or 2Hydrostar connector type SKK24Hirschmann connector type G4Circular connector M12x1 (Binder series 763)
0...10 m³/h (DN50) to 0...2000 m³/h (DN300) respectivelyNominal widths:DN50 to DN300 (optional with high pressure couplings, like SSKV heavy version)Nominal pressure ranges:10 bar (1 MPa) to 500 bar (50 MPa)Electrical connection:Terminals and cable glandPROMOS connector type BN4160Machaczek connector type ME2A10Souriau connector type 845, size 1 or 2Hydrostar connector type SKK24Hirschmann connector type G4Circular connector M12x1 (Binder series 763)
Output signal:
Frequency 5...15 HzCurrent 4...20 mAHousing:Steel and stainless steelGlassfibre reinforced duroplastic Polyester, graphite added (terminal housing)Electrode material:
1.4571 (316Ti)Bolt circle of the flanges according to:EN 1092-1Power supply:9.0...13.5 VDCCurrent consumption:max. 480 mAProtection acc. to EN 60529:IP 65Marking acc. 2014/34/EU (ATEX):I M1 Ex ia I (BVS 09 ATEX E 020)MA Safety Certificate:J2018166Ambient temperature:
-20...+60 °CProcess temperature:-20...+60 °CMeasuring uncertainty:Max. ± 1 % of end value, typ. ± 0.5 % of end valueTechnical Specifications
| Measuring principle: | Electromagnetic |
| Flow measuring ranges: | 0...100 l/min (DN50) to 0...1000 l/min (DN150) and 0...10 m³/h (DN50) to 0...2000 m³/h (DN300) respectively |
| Nominal widths: | DN50 to DN300 (optional with high pressure couplings, like SSKV heavy version) |
| Nominal pressure ranges: | 10 bar (1 MPa) to 500 bar (50 MPa) |
| Electrical connection: |
|
Output signal: |
|
| Housing: |
|
Electrode material: | 1.4571 (316Ti) |
| Bolt circle of the flanges according to: | EN 1092-1 |
| Power supply: | 9.0...13.5 VDC |
| Current consumption: | max. 480 mA |
| Protection acc. to EN 60529: | IP 65 |
| Marking acc. 2014/34/EU (ATEX): | I M1 Ex ia I (BVS 09 ATEX E 020) |
| MA Safety Certificate: | J2018166 |
Ambient temperature: | -20...+60 °C |
| Process temperature: | -20...+60 °C |
| Measuring uncertainty: | Max. ± 1 % of end value, typ. ± 0.5 % of end value |