Aron AD5RI211Z2003 Valve
기술 데이터시트 / 제품 문서
| 브랜드 | |
| 카테고리 | 밸브 |
| 제품명 | Aron AD5RI211Z2003 Valve |
| 제품 코드 | AD5RI211Z2003 |
저희에게 연락하세요! 영업일 기준 24시간 이내(주말 및 공휴일 제외) 재고 상태와 예상 납기를 안내해 드립니다.
제품 설명
Aron의 Aron AD5RI211Z2003 Valve을(를) 포함한 제품은 병행 수입 채널을 통해 조달되며 United States의 고객에게 신속하고 안정적으로 배송됩니다. Imtek Engineering은 경쟁력 있는 가격으로 정품 Aron 부품을 제공합니다. Aron AD5RI211Z2003 Valve이 당사 웹사이트에 등록되어 있지 않더라도 언제든지 견적을 요청하실 수 있으며, 담당 팀이 신속히 답변 드릴 것입니다.
AD.5.E...J* VALVES WITH SPOOL MOVEMENT SPEED CONTROL VARIANT J*
1
Valves type AD5.E... with spool movement speed control.
These ON-OFF type valves are used when a lower spool movement speed than usual for conventional solenoid valves is required to prevent
impacts which could adversely affect the smooth running of the system.
The system consists of reducing the transfer section for the fluid from one solenoid to the other by means of calibrated orifice.
• This version can only be used with a direct current (DC) and also involves a reduction in the limits of use so that we suggest to always
test the valve in your application.
• To order AD.5.J* version valves, specify the orifices code.
• The operation is linked to a minimum counter-pressure on the T line (1 bar min.)
• The switching time referred to the spool travel detected by a
LVDT transducer can vary for the NG10 valve a minimum of 200 to a maximum of 400 ms depending on 5 fundamental variables:
1) Diameter of the calibrated orifice (see table)
2) Hydraulic power for clearance referring to flow and pressure values through the valve
3) Spool type
4) Oil viscosity and temperature
5) Counter-pressure at T line
• Possible mounting: C / E / F / G / H
• 19 / 20 / 21 spools not planned for AD.5.E...J*
Max. pressure ports P/A/B Max. pressure port T - see note (*) Max. flow Duty cycle
Fluid viscosity Fluid temperature Ambient temperature Weight with one DC solenoid
Weight with two DC solenoids
320 bar 250 bar 100 l/min 100% ED 10 ÷ 500 mm2/s -25°C ÷ 75°C -25°C ÷ 60°C
3,6 Kg 4,5 Kg
(*) Pressure dynamic allowed for 2 millions of cycles.
CALIBRATED
ORIFICE AVAILABLE
ø (mm) 0.5 0.6 0.7 0.8
M6x6
Code
M89.10.0031 M89.10.0026 M89.10.0032 M89.10.0033
5S (J5+S1)* 6S (J6+S1)* 7S (J7+S1)* 8S (J8+S1)*
* Old code
EAD5E...J$ - 00/2000/e
E = Manual override Fixing screws UNI 5931 M6x40 with material specifications min. 8.8
Tightening torque 8 Nm / 0.8 Kgm
Support plane specifications
AD.5.E...Q5 VALVES WITH EXTERNAL DRAINING SOLENOID - VARIANT Q5 Valves type AD5.E...Q5 with external draining solenoid.
This involves valves with solenoid drainage chambers separated by line T in the CETOP 5 interface distinguished by the letter L.
This solution makes it possible to operate with a maximum counterpressure at T up to 320 bar using only 12.9 material fixing screws to
ensure the maximum safety of the solenoid valve fixing and use of an additional drain. This version can be used for direct current (DC)
and alternating current (AC), but involves a reduction in the limits of usage depending on the pressure at T.
• Mounting possible: C / D / E / F / G / H / I / L / M
• For subplate see BSH.5.31..
OVERALL DIMENSIONS
Max. pressure ports P/A/B/T 320 bar Max. pressure port L (DC coils) see note (*)
250 bar Max. pressure port L (AC coils) 160 bar Max. flow 100 l/min Max. excitation frequency
2 Hz Duty cycle 100% ED Fluid viscosity 10 ÷ 500 mm2/s Fluid temperature
-25°C ÷ 75°C Ambient temperature -25°C ÷ 60°C Weight with one DC solenoid
3,6 Kg Weight with two DC solenoids 4,5 Kg Weight with one AC solenoid 3,5 Kg
Weight with two AC solenoids 4,3 Kg (*) Pressure dynamic allowed for 2 millions of cycles.
EAD5E...Q5 - 02/2000/e
E = Manual override
Fixing screws UNI 5931 M6x40 with material specifications 12.9 must be used
Tightening torque 8 Nm / 0.8 Kgm
File: AD5EJ$2_E
Support plane specifications
I • 32
02/2000/e
1
Valves type AD5.E... with spool movement speed control.
These ON-OFF type valves are used when a lower spool movement speed than usual for conventional solenoid valves is required to prevent
impacts which could adversely affect the smooth running of the system.
The system consists of reducing the transfer section for the fluid from one solenoid to the other by means of calibrated orifice.
• This version can only be used with a direct current (DC) and also involves a reduction in the limits of use so that we suggest to always
test the valve in your application.
• To order AD.5.J* version valves, specify the orifices code.
• The operation is linked to a minimum counter-pressure on the T line (1 bar min.)
• The switching time referred to the spool travel detected by a
LVDT transducer can vary for the NG10 valve a minimum of 200 to a maximum of 400 ms depending on 5 fundamental variables:
1) Diameter of the calibrated orifice (see table)
2) Hydraulic power for clearance referring to flow and pressure values through the valve
3) Spool type
4) Oil viscosity and temperature
5) Counter-pressure at T line
• Possible mounting: C / E / F / G / H
• 19 / 20 / 21 spools not planned for AD.5.E...J*
Max. pressure ports P/A/B Max. pressure port T - see note (*) Max. flow Duty cycle
Fluid viscosity Fluid temperature Ambient temperature Weight with one DC solenoid
Weight with two DC solenoids
320 bar 250 bar 100 l/min 100% ED 10 ÷ 500 mm2/s -25°C ÷ 75°C -25°C ÷ 60°C
3,6 Kg 4,5 Kg
(*) Pressure dynamic allowed for 2 millions of cycles.
CALIBRATED
ORIFICE AVAILABLE
ø (mm) 0.5 0.6 0.7 0.8
M6x6
Code
M89.10.0031 M89.10.0026 M89.10.0032 M89.10.0033
5S (J5+S1)* 6S (J6+S1)* 7S (J7+S1)* 8S (J8+S1)*
* Old code
EAD5E...J$ - 00/2000/e
E = Manual override Fixing screws UNI 5931 M6x40 with material specifications min. 8.8
Tightening torque 8 Nm / 0.8 Kgm
Support plane specifications
AD.5.E...Q5 VALVES WITH EXTERNAL DRAINING SOLENOID - VARIANT Q5 Valves type AD5.E...Q5 with external draining solenoid.
This involves valves with solenoid drainage chambers separated by line T in the CETOP 5 interface distinguished by the letter L.
This solution makes it possible to operate with a maximum counterpressure at T up to 320 bar using only 12.9 material fixing screws to
ensure the maximum safety of the solenoid valve fixing and use of an additional drain. This version can be used for direct current (DC)
and alternating current (AC), but involves a reduction in the limits of usage depending on the pressure at T.
• Mounting possible: C / D / E / F / G / H / I / L / M
• For subplate see BSH.5.31..
OVERALL DIMENSIONS
Max. pressure ports P/A/B/T 320 bar Max. pressure port L (DC coils) see note (*)
250 bar Max. pressure port L (AC coils) 160 bar Max. flow 100 l/min Max. excitation frequency
2 Hz Duty cycle 100% ED Fluid viscosity 10 ÷ 500 mm2/s Fluid temperature
-25°C ÷ 75°C Ambient temperature -25°C ÷ 60°C Weight with one DC solenoid
3,6 Kg Weight with two DC solenoids 4,5 Kg Weight with one AC solenoid 3,5 Kg
Weight with two AC solenoids 4,3 Kg (*) Pressure dynamic allowed for 2 millions of cycles.
EAD5E...Q5 - 02/2000/e
E = Manual override
Fixing screws UNI 5931 M6x40 with material specifications 12.9 must be used
Tightening torque 8 Nm / 0.8 Kgm
File: AD5EJ$2_E
Support plane specifications
I • 32