Industrial spare parts & engineering solutions since 2001.
Gestra NRG 26-60 Level Electrode
기술 데이터시트 / 제품 문서
| 브랜드 | ![]() |
| 카테고리 | 레벨 |
| 제품명 | Gestra NRG 26-60 Level Electrode |
| 제품 코드 | NRG 26-60 |
저희에게 연락하세요! 영업일 기준 24시간 이내(주말 및 공휴일 제외) 재고 상태와 예상 납기를 안내해 드립니다.
제품 설명
Gestra의 Gestra NRG 26-60 Level Electrode을(를) 포함한 제품은 병행 수입 채널을 통해 조달되며 United States의 고객에게 신속하고 안정적으로 배송됩니다. Imtek Engineering은 경쟁력 있는 가격으로 정품 Gestra 부품을 제공합니다. Gestra NRG 26-60 Level Electrode이 당사 웹사이트에 등록되어 있지 않더라도 언제든지 견적을 요청하실 수 있으며, 담당 팀이 신속히 답변 드릴 것입니다.
OK
!
-
Level Electrode
NRG 26-60
+
Description
Technical data
The NRG 26-60 level electrode can be used with an
NRR 2-60 / NRR 2-61 level controller for continuously measuring the water level in steam boiler and hot-water plants or
in condensate and feedwater tanks.
Model and mechanical connection
■ In combination with the NRR 2-60/NRR 2-61 level controller, the electrode can be used as a level control system
with MIN/MAX alarm, for example.
■ The NRG 26-60 level electrode can be used in fluids with different conductivity.
Visualisation and operation take place via the URB 60 control terminal or SPECTORcontrol operating unit.
■ Thread G¾ A, EN ISO 228-1 Nominal pressure rating, admissible service pressure and temperature
■ PN 40 32 bar (abs) at 238°C Materials ■ Terminal box: 3.2581 G AlSi12, powder-coated
■ Sheath: 1.4301 X5 CrNi 18-10 ■ Electrode rod insulation: PTFE ■ Screw-in body: 1.4571, X6CrNiMoTi17-12-2
NRG 26-60
Function The NRG 26-60 level electrode works using the capacitance measurement principle and converts the information on the
water level into a data telegram. The 0-100% measuring range can be scaled by modifying the effective length of
the electrode rod.
Automatic self-test An automatic self-test cyclically monitors the safety and function of the level electrode and measured value acquisition.
Faults in the electrical connection or electronic measuring equipment trigger fault indications and alarms.
The data are transferred to the NRR 2-6x level controller via an ISO 11898 CAN bus in the CANopen protocol.
pH value ■ Maximum admissible = 10 Max. installed length at 238°C, all measurements in mm
■ see “How to order and specify”, Fig. 1 table ■ Do not shorten the electrode rod.
Measurement quality The information below applies to a fluid conductivity range
from 0.5 – 10000 µS/cm adjusted for temperature based on 25°C.
■ Reading error:
± 1% of set measuring range at the operating point ■ Resolution of reading on display: 0.1 %
■ Resolution for internal processing: 15 bit ■ Sensitivity (minimum conductivity)
◆ Water ≥ 0.5 μS/cm Supply voltage ■ 24 V DC ± 20% Power consumption ■ Max. 7 W
Current input ■ Max. 0.3 A Internal fuse ■ T2A Safety cutout at excessive temperature
■ Cutout occurs when an excessive temperature = 75°C is measured in the electrode tip
Input/output ■ Interface for CAN bus to ISO 11898, CANopen, insulated ■ M12 CAN bus connector, 5-pin, A-coded
■ M12 CAN bus socket, 5-pin, A-coded
자주 묻는 질문
Gestra의 Gestra NRG 26-60 Level Electrode에 관한 자주 묻는 질문입니다. Imtek Engineering은 United States에서 Gestra의 Gestra NRG 26-60 Level Electrode를 조달하는 데 도움을 드릴 준비가 되어 있습니다.
Imtek Engineering은 신뢰할 수 있는 공급 채널을 통해 정품 Gestra 제품을 조달하여 United States 고객에게 경쟁력 있는 가격으로 제공합니다.