Industrial spare parts & engineering solutions since 2001.
Rotork IQT DC electric actuator
기술 데이터시트 / 제품 문서
| 브랜드 | |
| 카테고리 | 액추에이터 |
| 제품명 | Rotork IQT DC electric actuator |
| 제품 코드 | 미지정 |
저희에게 연락하세요! 영업일 기준 24시간 이내(주말 및 공휴일 제외) 재고 상태와 예상 납기를 안내해 드립니다.
제품 설명
Rotork의 Rotork IQT DC electric actuator을(를) 포함한 제품은 병행 수입 채널을 통해 조달되며 United States의 고객에게 신속하고 안정적으로 배송됩니다. Imtek Engineering은 경쟁력 있는 가격으로 정품 Rotork 부품을 제공합니다. Rotork IQT DC electric actuator이 당사 웹사이트에 등록되어 있지 않더라도 언제든지 견적을 요청하실 수 있으며, 담당 팀이 신속히 답변 드릴 것입니다.
Design specification
5.1
Duty rating
Duty classification*
Actuator type
Rating
On-Off & Inching IQ
Nominal 60 starts per hour at a rate not exceeding 600 starts per hour.
15 minutes rated based on a nominal torque of 33% of rated
On-Off & Inching IQT
Nominal 60 starts at a rate not exceeding 600 starts per hour.
15 minutes rated based on a nominal torque of 75% of rated
Modulating IQM
Nominal 1,200 starts per hour, 50% duty cycle based on a modulating torque of 50% of rated torque
Modulating IQTM
Nominal 1,200 starts per hour, 50% duty cycled based on a modulating torque of 50% of rated torque
5.2
Design life
Duty classification*
Actuator type
Size
On-Off & Inching IQ 10-35
Minimum design life rating Torque and thrust test: 10,000 cycles (500,000
output turns) seating at rated torque, 33% rated torque through stroke
40-95 Torque and thrust test: 5,000 cycles (250,000
output turns) seating at rated torque, 33%
rated torque through stroke
Modulating IQM 12-35 1,800,000 starts at load of 50% rated torque
(1 start constitutes at least 1° movement) On-Off & Inching IQT All sizes
Torque test: 25,000 cycles seating at rated torque, 70% rated torque through stroke
Modulating IQTM All sizes
1,800,000 starts at load of 70% rated torque (1 start constitutes at least 1° movement)
Design life is a function of actuator torque and speed. Values quoted are the minimum requirements; for most sizes/speeds life will be
extended above the values quoted. Actuators are stalled against a solid object 25 times to prove durability.
Contact Rotork for more information
5.3
Vibration, shock and noise
Standard IQ and IQT Pro Range actuators are suitable for applications where vibration and shock severity does not exceed the following:
Type
Level
Plant induced vibration
1g rms total for all vibration within the frequency range of 10 to 1000 Hz
Shock
5g peak acceleration
Seismic
2g acceleration over a frequency range of 1 to 50 Hz if it is to operate during and after the event
Emitted noise
Independent tests have shown that at 1m generated noise does not exceed 61 db(A)
Levels quoted are those present at the actuator mounting interface. It should be noted that the effects of vibration are cumulative and
therefore an actuator subjected to significant levels may have a reduced lifespan. Where excessive plant induced vibration is anticipated,
mounting the actuator remote from the valve and driving via extension shafting (incorporating vibration absorbing couplings) may provide a
satisfactory solution.
29