Leistritz products, including Leistritz L3Mf060 Pump, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Leistritz parts at competitive prices. Even if Leistritz L3Mf060 Pump is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.
6.2 Checking operation How to check the pump unit during operation:
1.
Make sure that the differential pressure is at least 1 - 1,5 bar.
2.
Check the pump unit for excessing power consumption, vibrations, increased temperature and leakages. ⮫ Further
information on page 61 🡆 The vibration level must not exceed 4.5 mm/s (rms) continuously or 7.1 mm/s (rms) during the transition states
(guide values).
🡆 The sound pressure level must not exceed the values in the “Technical data” chapter. ⮫ Appendix A ‘Technical data’
on page 69
3.
Check the shaft seal for leakages.
4.
Carry out a visual inspection of the pump unit at least once a month. ⮫ ‘How to visually inspect the pump unit:’ on page 61
5.
Check the operating data (total delivery pressure, delivery rate, viscosity, temperature, speed, power consumption,
etc.). ⮫ Appendix A ‘Technical data’ on page 69
6.
Check the set valve pressure. ⮫ Chapter 9.9 ‘Test the pressure relief valve’ on page 62
6.3 Check the suction-side pressure How to test the suction-side pressure:
Use the pressure sensor installed in the system to check the suction side pressure. Note the information in the Technical
data. ⮫ Appendix A ‘Technical data’ on page 69
6.4 Test the overflow valve How to check the overflow valve:
Check the system pressure using the overflow valve installed in the system. Note the information in the Technical data.
⮫ Appendix A ‘Technical data’ on page 69
6.5 Setting the aeration The damping of the noises can be set via the adjustable aeration if
necessary.
48
Screw pump L3MF IFOKSO-W
21.09.2023