Meggitt Vibro-Meter VM600 CPUM Modular CPU Card
Meggitt
Product Code: Vibro-Meter VM600 CPUM
Brand: Meggitt
GET OFFER: info@imtek.com.tr
Description for Meggitt Vibro-Meter VM600 CPUM Modular CPU Card
Ordering number (PNR)601-003-000-VVV\3\610-1CC-CCC (equivalent to a 200-595-0Ss-33h with a configuration)601-003-000-VVV\3V\610-1CC-CCC (equivalent to a 200-595-0Ss-33hl with a configuration)601-003-000-VVV\5\610-1CC-CCC (equivalent to a 200-595-0Ss-53h with a configuration)VM600 rack controller and communications interface card.The VM600 CPUM and IOCN modular CPU card and input/output card is a rack controller and communications interface card pair that acts as a system controller and data communications gateway for a VM600 rack-based machinery protection system (MPS) and/or condition monitoring system (CMS) from Meggitt’s Vibro-Meter® product line.Note: Different versions of CPUx/IOCx rack controller and communications interface card pair are available, as follows:• The CPUM/IOCN is the original version with a front-panel display and support for Modbus RTU/TCP or PROFINET (PNR 200-595-VVV-VVV).• The CPUR/IOCR is a version with rack controller redundancy and support for Modbus RTU/TCP (PNR 600-007-VVV-VVV).• The CPUR2/IOCR2 is a version with mathematical processing of fieldbus data and support for Modbus TCP and PROFIBUS DP (PNR 600-026-000-VVV).FeaturesVM600 CPUM/IOCN rack controller and communications interface card pair with support for Modbus RTU/TCP or PROFINET, and a front-panel display“One-Shot” configuration management of protection cards (MPC4 and AMC8) in a VM600 rack using an Ethernet or RS-232 serial connection to a computer running the VM600 MPSx softwareFront-panel display for visualisation of monitored outputs and alarm limits from protection cardsCommon alarm reset (AR) for protection cards and VM600 MPS rack (CPUM) securityVM600 system event and measurement event logs available via the VM600 MPSx software PARAMETER VALUE (IMPERIAL | METRIC) Monitoring system (application) Machinery protection, condition monitoring, combustion monitoring VM600 system function Common VM600 system component Processing card VM600 component function Rack controller and communications interface VM600 component and rack compatibility ABE040, ABE042 VM600 communications interfaces Modbus RTU/TCP or PROFINET VM600 rack alarm reset (AR) Yes VM600 MPS rack (CPUx) security Yes VM600 event logs System event and measurement event logs (up to 10000) VM600 output relays 0Recommended Products For Meggitt
Eurotherm EPC3004/CC/VH/D1/XX/R2/XX/XX/XX/XX/XX/XX/ST/ XXXXX/XXXXXX/XX/1/P/2/X/X/X/X/X/X/C/XX/XX/XX/ Controller Eurotherm EPC3004/CC/VH/D1/XX/R2/XX/XX/XX/XX/XX/XX/ST/ XXXXX/XXXXXX/XX/1/P/2/X/X/X/X/X/X/C/XX/XX/XX/ Controller