TECHNICAL DETAILSDetection propertiesNominal detection distance? 16mResolution500mmControlled height500mmNumber of spokes2Effective opening angle? ± 2.5 °ApplicationPrinciple of operationEmitter + ReceiverAvailable functions
Manual / Automatic restart,
EDM, Barrier status
Security parametersGuy4SIL3SILCL3PLisPFHd7,53E-09DCavg97.94%MTTFd100CFF80%OutputsType of output
2 x PNP-NO
(OSSD safety outputs)
Response time7msElectrical dataSupply voltage19.2 ... 28.8 VdcLoad current500mADelay in availability15sImmunity to ambient light
According to
IEC 61496-2
Power consumption - Receiver6WAbsorbed power - Emitter3WEquivalent resistive load? 48 ?Capacitive load tolerated? 2 µFCable length (power supply / output)100mMechanical datadimensions50mm (front) x 60mmConnections
M12-5 poles
(emitter) M23-19 poles
(receiver)
Operating temperature0 ° C ... + 55 ° CStorage temperature-25 ° C ... + 70 ° CHumidity
95%
(without consent)
Testing / CertificationsCertificationsCE, cULus, TÜVElectromagnetic compatibility
According to
Directive 2014/30 / EU
Shock and vibration
According to
IEC 61496-1
Degree of protectionIP65AccessoriesAccessories included
ST 202,
ST 203