Detection propertiesNominal detection distance
According to
the sensors
used: SH4 / * - ** IA up to
10m TH6 / * - * IA up
to 60m
ApplicationPrinciple of operationControl unitAvailable functions
Manual / Automatic
Restart, EDM
Maximum number of sensors connected
6 x pairs SH4
_IA / TH6_IA
Status lamp output
1 x incandescent lamp
(1… 10W, 24Vdc)
Security parametersGuy2SIL1SILCL1PLcPFHd1.00E-06MTTFd20OutputsType of output
2 x PNP - NO
(OSSD safety output)
Response time? 12msResponse time (test input)? 30msResponse time (muting function)? 270msRecovery time? 50msElectrical dataSupply voltage16.8 ... 28.8 VdcVacuum absorption100 mALoad current2 x 500mAOutput voltage drop2.5V @ 500mACable length (power supply / output)
? 30m (0.5mm2 cable
section) ? 60m
(2.5mm2 cable section)
Cable length (sensors)
? 100m
(2mm2 cable section)
Residual ripple? 5%Absorbed power
4W (without
lamps / loads)
Mechanical datadimensions99 x 105 x 100mmBody materialABS UL VOConnections1 x terminalsOperating temperature
20 ° C ... + 60 ° C
(without ice)
Storage temperature
-25 ° C ... + 75 ° C
(without ice)
Humidity
15% ... 95%
(without condensation)
Testing / CertificationsCertificationsCE, TÜVDegree of protectionIP20