Detection propertiesNominal detection distance60m (ExG = 2)Thermal drift? 10%ResolutionLight barriersControlled heightLight barriersEffective angular openingTypical ± 1.8 °ApplicationPrinciple of operationEmitterNote
Not to be used with
SBCR03 control unit.
Must be used with
external control unit wit
h optical test function.
Security parametersGuy2SIL1SILCL1PLcPFHd1.00E-06MTTFd20Electrical dataSupply voltage10 ... 30 VdcVacuum absorption? 25mAMaximum residual ripple? 5 VppLED indicatorsYellow (power)IssuanceRed LedMechanical datadimensionsM30Body materialPBTConnectionsM12 plugActive part materialGlassOperating temperature-20 ° C ... + 55 ° CStorage temperature-40 ° C ... + 75 ° CHumidity15% ... 95%Testing / CertificationsCertificationsCE, TÜVShock and vibration
10g - 16ms
(according to
IEC600068-2-29)
10Hz ... 55Hz - 1 oct / min - 0.35mm
(according to
60068-2-6)
Degree of protectionIP67AccessoriesAccessories included2 x ferrules