Mts Sensor C OEM ANALOG Position Sensors


Mts Sensor C OEM ANALOG  Position Sensors Image

Are you interested in the product Mts Sensor C OEM ANALOG Position Sensors from manufacturer Mts Sensor with code C OEM ANALOG? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for Mts Sensor C OEM ANALOG Position Sensors from our live support team now!

nputMeasured value: PositionStroke length: 72, 109, 128, 148, 162, 186, 194, 217, 250 mmOutputVoltage: 0.1 - 4.9 VDCResolution: analog output signalSignal without magnet: not specifiedFeature: At 5 VDC operating voltage output is ratiometric to operating voltageAccuracyLinearity: ± 0.15 mm by means of magnet 401842, between 5 % and 95 % of stroke lengthZero tolerance: ± 1 mmHysteresis: ± 25 µmRepeatability: ± 25 µmTemperature coefficient: ± 0.005 % per °CUpdate time: 500 Hz (2 ms)Operation conditionsOperating temperature: -40 °C…+75 °CStorage temperature: -20 °C…+85 °CPressureup to 2500 m altitudeIP ProtectionIP303 - DIN 40 050 Part 9 – Protection against foreign bodies – Protected against foreign bodies from Ø 2.5 mm0 - DIN 40 050 Part 9 – Protection against water – No protectionEnvironmental testingShock test: IEC-68-2-2710 g (11 ms) –> Single hit10 g (11 ms) 1000 shocks per axisVibration test: IEC 60068-2-6 (10…2000 Hz) 10 g Sinus (resonance frequencies excluded)EMC-test: Emission according to EN 61000-6-4 CISPR 16-2-3 – Disturbance field strength (measurement distance 3 m) CIPSR 16-2-1 – Disturbance current (DC voltage supply) Immunity according to EN 61000-6-2EN 61000-4-2 – Electrostatic discharge (ESD) (Compliance only with corresponding protection housing, see H2 and M1)EN 61000-4-3 – Radiated electrosolenoidic radio-frequency, free radiated (Compliance only with corresponding protectionhousing, see H2 and M1)EN 61000-4-4 – Electrical fast transient (Burst)EN 61000-4-5 – SurgeEN 61000-4-6 – Conducted radio-frequency, line guidedEN 61000-4-8 – Power frequency solenoidic fieldForm factor, materialHousing: POMProtective pipe: nylon blueElectrical connectionSupply voltage: CS: 5 VDC (tolerance range 4.75 - 5.5 VDC), CM: 12 VDC (tolerance range 9 - 15 VDC)Max. power consumption: max. 40 mAOutput load: analog: > = 10 k?Overvoltage protection: CS: up to 19 VDC short termCM: up to 29 VDC short termPolarity protection: VDC - GNDOperating voltage quality: CS: 5 VDC CM: 12 VDCLoad control: ± 0.1 % ± 0.15 %Grid control: ± 0.05 % ± 0.05 %Ripple: < 50 mVpp < 100 mVppMechanical connectionScrew connection: 2 screws M3 x 37, max. tightening torque 0.4 Nm, with 3 mm bore holeTerminal connection: by means of O-rings (consultation with MTS required)