Types: TFP-41 / TFP-51 / TFP-161 / TFP-181
Flow optimized temperature measurement for tubes from DN15 on and vessels, with hygienic thread M12 (CLEANadapt)
For the monitoring of production and CIP-/SIP processes and UHT plantsExtremely robust and long lasting, completely made of stainless steelSensor tips with ø 6, 4 oder 3 mm for shortest response timesMany options and variations for individual adaptationTechnical SpecificationProcess ConnectionCLEANadapt G1/2"Insertion length20…500 mmWetted materialStainless steel 1.4404 (316L), Ra?0.8 ?mMeasuring range-50…+250°C, Option up to +450°CAccuracyA | 1/3B | 1/10BAvailable versionsHead ø18 mm |ø 55 mm | High-temperature | Transmitter | LCD displayOperating pressuremax. 50 barCommunicationPt100, 4..20 mA