im-tek.com

NSD VS-5FD-1 VARICAM Cam Switch Output Controller

NSD

Product Code: VS-5FD-1 VARICAM
Brand: NSD



GET OFFER: info@imtek.com.tr

Description for NSD VS-5FD-1 VARICAM Cam Switch Output Controller

Model codingVS-5F[1][2]-[3][1]No. of programs×No. of switch outputs , and othersCodeOutput codeBlank1 program×24 switchesD8 programs×24 switches, current position BCD output.X16 programs×40 switches or 32 programs×24 switches, current position BCD output.[2]Output systemCodeOutput systemBlankSink type[3]Power supply voltageCodeSpecification124VDCContact us about other specifications.ABSOCODER Basic Configuration SpecificationGeneral specificationItemSpecificationConverter modelVS-5F-1VS-5FD-1VS-5FX-1Power supply voltage24VDCPermissible powervoltage range21.6 ? 30VDCPower consumption10W or lessInsulation resistance20M? or more between external AC power terminals and ground(by 500 VDC insulation resistance tester)Withstand voltage500 VAC, 60Hz for 1 minutebetween external DC power terminals and groundVibration resistance20m/s2 10 ? 500Hz, 10cycles of 5 minutes in 3 directions,conforms to JIS C 0040 standardAmbient operatingtemperature0 ? +55? (No freezing)(Surrounding air temperature rating of 55? maximum)Ambient operatinghumidity20 ? 90 %RH (No condensation)Ambient operatingenvironmentFree from corrosive gases and excessive dustAmbient storagetemperature-10 ? +70?GroundingMust be securely grounded (ground resistance of 100 ohm or less)ConstructionInside control panelMountingSelect from two-screw mounting/DIN rail installation/on-panel mounting using panel mounting fixture VS-K-F.Outside dimension (mm)130(W)×81(H)×99(D)MassApprox. 0.7kgPerformance SpecificationItemSpecificationConverter modelVS-5F-1VS-5FD-1VS-5FX-1Applicable sensorVRE-P028,VRE-P062Min. setting units0.5°Number of programs (Panel display)18(0 ? 7)16(0 ? 15)32(0 ? 31)Number of switch outputs24244024Number of multi-dogs10 times for each switch output (0 ? 9)Position data sampling time(permissible speed)0.176ms (900 r/min When ON / OFF range is 1 degree)Switch output setting methodNumerical setting from the panel or teachingSetting value memoryNon-volatile memories (FRAM)Error detectionSensor power error, Sensor error , Memory error , No setting error , Setting impossible error , System errorAuxiliary functionsProtected switch???Setting changeduring operation???Current position value(BCD, gray code(720-division))-??Binary speed output-Selectable between current position output and speed outputSelectable between current position output and speed outputTiming pulse output???Motion detection switchSelectable between timing pulse and speed detection outputSelectable between timing pulse and speed detection outputSelectable between timing pulse and speed detection outputSwitch output enable???Hysteresis???Exterminal origin set--?Arbitrary pulse output???Current position HOLD-??Error cancel???Password???Communication functionSerial (RS-232C) communication (setting value saving or loading, monitoring, operation commands)Connection by Mitsubishi-only protocol/MELSEC-A protocolConnection with angle display unit (NDP) is also possibleConnection by OMRON-only protocolConnection with touch panel is possible (VARIMONI)Connection ofan external display unitI/O connection-??Communicationconnection???Max. sensorcable lengthStandard100mRobotic(RBT)100mI/O spcificationItemVS-5F-1VS-5FD-1VS-5FX-1DescriptionInputsignalsProgram No.-3 points4/5 pointsInputs the exteral program No.Current position HOLD-1 point-Used to prevent the current position value from changing when controller reading occurs.Current position HOLD orexternal origin set--1 pointInput to prevent current position from changing or for origin setting.Error cancel1 point1 point1 pointInput to cancel an error display.Switch output enable1 point1 point1 pointSwitch signal will be output only upon the input of this signal.OutputsignalsSwitch output /Arbitrary pulse output24 points24 points40/24 pointsON/OFF signal will be output based on the switch setting value, or pulse signalwill be output based on equally dividing a single rotation (division selectable from 1 ? 360).Timing pulse /Motion detection switch1 point2 points1 point60, 180 or 360 pulse signals will be output per rotation, or ON/OFF signal will be output based on the speed setting value.System ready1 point1 point1 pointOutputs when controller and sensor are functioning normally.Program No.-3 points4/5 pointsThe currently selected Program No. is output.Current position value(BCD, gray code(720-division)) /Speed Binary output-11 points11 pointsCurrent position (3-digit BCD + 0.5-deg display) signal will be output, or rotational speed will be output in binary code.Latch pulse-1 point1 pointOutputs a timing signal which ensures that the current position is read in a stable condition.ItemInput specificationsItemOutput SpecificationsInput signalsProgram No.External origin setCurrent position HOLDError cancelSwitch output enableOutput signalsSwitch output or arbitrary pulseProgram No. Sysytem readyMotion detection switch or timing pulseCurrent position value (BCD, gray code (720-division)) or speed (binary)latch pulseInput circuitDC input, photo-coupler isolationOutput circuitTransistor (open-collector), photo-coupler isolationInput logicNegative logicOutput logicNegative logicNegative logicPositive logic*1Rated input voltage

Recommended Products For NSD


NSD MRE-G320SP062FAC Multi-turn type ABSOCODER Sensor
NSD MRE-G64SP062FAC Multi-turn type ABSOCODER Sensor
NSD MRE-G160SP062FBC Multi-turn type ABSOCODER Sensor
NSD VLS-512PW350B Linear Type ABSOCODER Sensor
NSD NDP-A221A1 External Display Unit for VARICAM
NSD MRE-32SP062FAC Multi-turn type ABSOCODER Sensor
NSD MRE-G320SP062FBC Multi-turn type ABSOCODER Sensor
NSD VLS-512PWB Linear Type ABSOCODER Sensor
NSD VS-10G-A-1 VARILIMIT Limit Switch Output Controller
NSD NDP-A211B1 External Display Unit for VARICAM
NSD MRE-G64SP062FBC Multi-turn type ABSOCODER Sensor
NSD MRE-G256SP062FBC Multi-turn type ABSOCODER Sensor
NSD MRE-G160SP062FAC Multi-turn type ABSOCODER Sensor
NSD VLS-256PW128B Linear Type ABSOCODER Sensor
NSD VS-5F-1 VARICAM Cam Switch Output Controller
NSD MRE Series Heavy Duty Multi-turn type ABSOCODER Sensor
NSD VRE-16TS062FAL Single-turn Type ABSOCODER Sensor
NSD VLS Series Heavy Duty Linear Type ABSOCODER Sensor
Aeco FT18ELCBRNPN FT18ELCBRNPN NO+NC RICEVITORE
Grundfos MTR 1S-17/17 A-W-A-HUUV Immersible Pump
Gefran LT-F-0500-S 0000X000N00 Potentiometer
Topworx 21-1151700 - 3/8Inch Side Sensing, SPDT, CSA GP, Brass With Black Lacquer Coating, Model 21 Go Switch
Fisher 1052PSV Size 60 Rotary Actuator
MBS MLW 139 4 34 1 3000 Sanitary Mixflo Multitube
Senseca FF-015RMS-138 Flow Switch
Bimba DM1-400x0.125-FB Dyna-Mation DM1 Cylinder
Greisinger GGA570 Atmospheric Oxygen Sensor
Gefran LT-M-0150-S 0000X000X00 Potentiometer
Hengstler AC58/1212EQ.42DNR Absolute Encoder
Gefran LT-F-0300-S L000X000X0N Potentiometer
Habasit UM220SC-B-N Heavy Conveyor Belt
Greisinger GRS3105 Interface Converter
Habasit IA2-LT Power Transmission Belt
Stego 14001.0-00 c4164 30w Anti-condensation Heater
Habasit Felt Top Food Belt
Faulhaber 1512U012SR 112:1 DC-Gearmotor
Goldammer NR70-VR50Φ 20-L385-02-L1/340/W-L2/270/W L3/230/WSO/ IN105.384 CG Level Regulator for Tank Insert
Vulcanic 2118-32 Screw Plug Immersion Heater
Sai GM2 630 1HD 310 Hydraulic Motor
Gemü Gemü 9601 8D A00TW 88285731 Plastic Operator
Gefran LT-F-0300-P 0000X000A0N Potentiometer
Kadant GA009015831 G Rotary Union