Product Name: Nuovafima 8.X09.AAFG.41M.T4B Intrinsically Safe Pressure Transmitter
Brand: Nuovafima
Product Code: 8.X09.AAFG.41M.T4B Intrinsically Safe Pressure Transmitter
Tags: Nuovafima
Are you interested in the product Nuovafima 8.X09.AAFG.41M.T4B Intrinsically Safe Pressure Transmitter from manufacturer Nuovafima with code 8.X09.AAFG.41M.T4B Intrinsically Safe Pressure Transmitter? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!
Get Offer With E-Mail: info@im-tek.com
Get a offer for Nuovafima 8.X09.AAFG.41M.T4B Intrinsically Safe Pressure Transmitter from our live support team now!
gnition protection Ex ia as per EN 60079-0, EN 60079-11, EN 60079-26, atmosphere typeGD :- category 1 (1), marking II 1 GD Ex ia IIC Ex ia IIIC (cod. 1GD);- category 1/2, marking II 1/2 GD Ex ia IIC Ex ia IIIC (cod. 2GD).Temperature classes (2),-T6 (T85°C)Ta ? 60 °C (cod. T6B);-T5 (T100°C)Ta ? 80 °C (cod. T5B);-T4 (T135°C)Ta ? 100 °C (cod. T4B).Measuring ranges: 0...1/0...1000 bar, relative; -1...0/-1...+24 bar, relative;0...1/0..25 bar, absolute.Output signal: 4...20 mA (cod. 1).Non-linearity (BFSL): ? ± 0,175 % of the range, according to IEC 61298-2.Non-repeatability: ? 0,1 % of the range, according to IEC 61298-2.Accuracy: ? ± 0,35% of the range (3).Thermal drift: between 0 and 80°C, 1% of span; 2,5% of span, max (4).Long term drift: ? 0,1 % of span.Zero and span adjustement: ± 10 % span typical.Stocking temperature: -30...+85 °C.Response time: <4 ms (measuring); <150 ms (switching on).Emission and immunity: according to EN 61326,(group 1 - class B; industrial applications).Vibration resistance: 20g (10...2000 Hz, according to IEC 60068-2-6).Shock resistance: 40g (6 ms, according to IEC 60068-2-27).Sensor: piezoresistive, with silicon oil.Case: in AISI 316L, vented up to 16 bar.Protection degree: IP 65 according to IEC 60529 (5).Process connection: in AISI 316L, hole ø 2,5 mm (with restrictor ø 0,7 mm for measuringranges ? 60 bar).Weight: 0,25 kg....(1) available with IP 68 metallic cable gland only;(2) “Tp” : fluid process temperature ? “Ta” : ambient temperature; “Tp” & “Ta” ? -20 °C.(3) max measuring error according to IEC 61298-2, including non-linearity and hysteresis (limit-point calibrationand reference conditions according to IEC 61298-1); accuracy ? ± 0,75% of span for measuring ranges 0...1 bar and0...600 bar.(4) + 0,5% of span for measuring range 0,6 bar(5) with properly assembled electric connection