RESIDUAL OIL CONTENT
0.01 mg/m³ @ 20 °C (XP), 0.5 mg/m³ @ 20 °C (ZP), n.a. (V), 0.003 mg/m³ @ 20 °C (A)
FILTER EFFICIENCY RATING
99.99% to 99.99999%, depending on filter type
ELEMENT CHANGE INTERVAL
12 months for V, ZP, XP elements / 3 months or max. 1500 hours of operation for A elements
MAXIMUM FLOW RATE
188 to 2787 (@100 barg) m3/hour
111 @ 1450 psig to 1640 @ 1450 psig CFM
MAXIMUM OPERATING PRESSURE
100 barg
1450 psig
MAXIMUM OPERATING TEMPERATURE
176 or 104, depending on filter type °F
MINIMUM OPERATING TEMPERATURE
1.5 °C
34.7 °F
MATERIALS OF CONSTRUCTION
Housing: Aluminum, anodized / Seals: NBR, Housing: Steel / Seals: NBR
WEIGHT
2.8, 3.4, 18.2, 21.9, 28.3, 39.2 kg
6.17, 7.49, 40.12, 48.28, 62.39, 86.42 lb
WIDTH
80, 116, 125 mm
3.15, 4.56, 4.92 inch
HEIGHT
355, 232, 420, 297, 455, 332, 540, 417, 655, 532, 910, 787 mm
13.97, 9.13, 16.53, 11.69, 17.91, 13.07, 21.26, 16.42, 25.78, 20.94, 35.82, 30.98 inch
CONNECTION TYPE
BSP-P (DIN ISO 228)
MICRON RATING
0.01, 1, 3, n.a., depending on filter type μm
DRAIN PORT SIZE
G1/4i
BRAND
Parker domnick hunter
PRE-TREATMENT REQUIREMENT
depending on filter type
SPECIFICATIONS MET
PED Fluid Group II, TR
APPLICATION
Filtration of compressed air and gaseous Nitrogen
Print Tech Specifications