Ropex products, including Ropex RES-402/230VAC Temperature Controller, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. As an authorized trading partner, Imtek Engineering offers genuine Ropex parts at competitive prices. Even if Ropex RES-402/230VAC Temperature Controller is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.
9
Technical data
Type of construction
Housing for installation in the electrical cabinet Snaps onto a standard top hat rail (DIN TS35 rail, 35mm) acc. to DIN EN 50022
Dimensions: 90 x 75mm; height: 135mm (incl. terminals)
Line voltage
All controllers manufactured as of January 2006:
115VAC version: 110VAC -15%…120VAC +10% (equivalent to 94…132VAC) 230VAC version: 220VAC -15%…240VAC +10% (equivalent to 187…264VAC)
400VAC version: 380VAC -15%…415VAC +10% (equivalent to 323…456VAC) All controllers manufactured up to December 2005:
115VAC version: 115VAC -15%…120VAC +10% (equivalent to 98…132VAC) 230VAC version: 230VAC -15%…240VAC +10% (equivalent to 196…264VAC)
400VAC version: 400VAC -15%…415VAC +10% (equivalent to 340…456VAC) Depending on the controller version ( section 12 "How to order" on page 31)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Auxiliary voltage Terminals 14+13
24VDC, +20%, -10%, reverse polarity-protected Current input: max. 1.0A
Heatsealing band type and temperature range
Default value 300°C, Alloy A20
Analog input (set point) Terminals 15+12
0…10VDC, Imax = 5mA, electrically isolated Equivalent to 0…300°C or with an external PD-3 precision potentiometer (R = 2kohms)
0…2kohms equivalent to 0…300°C
Analog output (actual value) Terminals 11+12
0…10VDC, Imax = 5mA, electrically isolated Equivalent to 0…300°C Accuracy: ±1% add. 50mV
Reference voltage
+10VDC / ±5%, Imax = 5mA
Digital logic levels Terminals 16, 17, 18
LOW (0V): 0…2VDC, electrically isolated
HIGH (24VDC): 12…30VDC (max. current input 6mA) Reverse polarity-protected
Alarm output
UON < 3V (saturation voltage), Imax = 200mA, electrically isolated, short-circuit proof
Maximum load (primary current of impulse transformer)
Imax = 5A (duty cycle = 100%) Imax = 25A (duty cycle = 20%)
Power dissipation
max. 20W
Ambient temperature
+5…+45°C
Degree of protection
IP20