Hirschmann
Hirschmann Spider 4Tx/1Fx-Eec 943221-101 Rail Switch
Product Code:Spider 4Tx/1Fx-Eec 943221-101 Rail Switch
Description
More InterfacesPower supply/signaling contact1 plug-in terminal block, 3-pin, no signal contactNetwork size - Length of cableTwisted pair (TP)0 - 100 mMultimode Fiber (MM) 50/125 µm0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x kmMultimode Fiber (MM) 62.5/125 µm0 - 4000 m, 11 dB Link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x kmNetwork size - CascadibilityLine - / star topologyanyPower requirementsOperating voltage9.6 VDC - 32 VDCCurrent consumption at 24 V DCmax. 150 mAPower consumptionmax. 3.9 W; 13.3 Btu(IT)/h at 24 VDCServiceDiagnosticsLEDs (power, link status, data, data rate)Ambient conditionsOperating temperature-40 C to +70 CStorage/transport temperature-40 C to +70 CRelative humidity (non-condensing)10% to 95%MTBF112 years, MIL-HDBK 217F: Gb 25 CMechanical constructionDimensions (W x H x D)25 mm x 114mm x 79 mmMountingDIN Rail 35 mmWeight120 gProtection classIP 30Mechanical stabilityIEC 60068-2-27 shock15 g, 11 ms duration, 18 shocksIEC 60068-2-6 vibration3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.EMC interference immunityEN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air dischargeEN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data lineEN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data lineEN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)EMC emitted immunityFCC CFR47 Part 15FCC CFR47 Part 15 Class AEN 55022EN 55022 Class AScope of delivery and accessoriesScope of deliverydevice, terminal block, operating manualAccessories to order separatelyRail power supply RPS 15, RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.EMC interference immunityEN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air dischargeEN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)EN 61000-4-4 fast transients (burst)2 kV power line, 4 kV data lineEN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data lineEN 61000-4-6 conducted immunity10 V (150 kHz - 80 kHz)EMC emitted immunityFCC CFR47 Part 15FCC CFR47 Part 15 Class AEN 55022EN 55022 Class AScope of delivery and accessoriesScope of deliverydevice, terminal block, operating manualAccessories to order separatelyRail power supply RPS 15, RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame
Technical Specifications
| More Interfaces | |
| Power supply/signaling contact | 1 plug-in terminal block, 3-pin, no signal contact |
| Network size - Length of cable | |
| Twisted pair (TP) | 0 - 100 m |
| Multimode Fiber (MM) 50/125 µm | 0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km |
| Multimode Fiber (MM) 62.5/125 µm | 0 - 4000 m, 11 dB Link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km |
| Network size - Cascadibility | |
| Line - / star topology | any |
| Power requirements | |
| Operating voltage | 9.6 VDC - 32 VDC |
| Current consumption at 24 V DC | max. 150 mA |
| Power consumption | max. 3.9 W; 13.3 Btu(IT)/h at 24 VDC |
| Service | |
| Diagnostics | LEDs (power, link status, data, data rate) |
| Ambient conditions | |
| Operating temperature | -40 C to +70 C |
| Storage/transport temperature | -40 C to +70 C |
| Relative humidity (non-condensing) | 10% to 95% |
| MTBF | 112 years, MIL-HDBK 217F: Gb 25 C |
| Mechanical construction | |
| Dimensions (W x H x D) | 25 mm x 114mm x 79 mm |
| Mounting | DIN Rail 35 mm |
| Weight | 120 g |
| Protection class | IP 30 |
| Mechanical stability | |
| IEC 60068-2-27 shock | 15 g, 11 ms duration, 18 shocks |
| IEC 60068-2-6 vibration | 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
| EMC interference immunity | |
| EN 61000-4-2 electrostatic discharge (ESD) | 6 kV contact discharge, 8 kV air discharge |
| EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
| EN 61000-4-4 fast transients (burst) | 2 kV power line, 4 kV data line |
| EN 61000-4-5 surge voltage | power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
| EN 61000-4-6 conducted immunity | 10 V (150 kHz - 80 kHz) |
| EMC emitted immunity | |
| FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
| EN 55022 | EN 55022 Class A |
| Scope of delivery and accessories | |
| Scope of delivery | device, terminal block, operating manual |
| Accessories to order separately | Rail power supply RPS 15, RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame |