IMTEK Engineering

SICK

SICK 1030015 type: ATM60-PAH13X13 Absolute encoder

Product Code:ATM60-PAH13X13

Description

PERFORMANCEMax. resolution (number of steps per revolution x number of revolutions)13 bit x 13 bit (8,192 x 8,192)Error limits G0.25° 1)Repeatability standard deviation σr0.1° 2)1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.INTERFACESCommunication interfacePROFIBUS DPCommunication Interface detailDPV0Data protocolProfile for encoders (07hex) – Class 2Address setting0 ... 127, DIP switches or protocolData transmission rate (baud rate)9.6 kBaud ... 12 MBaud, automatic detectionStatus informationLED green (operation), LED red ( bus activity)Bus terminationDIP switch 1)Initialization time1,250 ms 2)Position forming time+ 0.25 msSSISet (electronic adjustment)Via PRESET push button or protocol1) Should only be connected in the final device.2) Valid positional data can be read once this time has elapsed.ELECTRICAL DATAConnection typeConnection adapter for PROFIBUS 1)Supply voltage10 ... 32 VMTTFd: mean time to dangerous failure150 years (EN ISO 13849-1) 2)1) Please order the bus adaptor seperately.2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.MECHANICAL DATAMechanical designBlind hollow shaftShaft diameter15 mm 1)Weight0.59 kgShaft materialStainless steelFlange materialAluminumHousing materialAluminum die castStart up torque1.2 Ncm, with shaft sealOperating torque0.8 Ncm, with shaft sealPermissible shaft movement, axial static/dynamic± 0.5 mm, ± 0.2 mmPermissible shaft movement, radial static/dynamic± 0.3 mm, ± 0.1 mmPermissible Load capacity of shaft

300 N / radial

50 N / axial

Moment of inertia of the rotor55 gcm²Bearing lifetime3.6 x 10^9 revolutionsAngular acceleration≤ 500,000 rad/s²Operating speed≤ 3,000 min⁻¹ 2)1) Collets for 6, 8, 10, 12, 14 mm and 1/4Inch, 3/8Inch and 1/2Inch as accessories, separate order item. For 15 mm shaft diameter collet is not needed.2) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.AMBIENT DATAEMCAccording to EN 61000-6-2 and EN 61000-6-3Enclosure rating

IP67, with shaft seal (according to IEC 60529) 1)

IP43, without shaft seal, on encoder flange not sealed (according to IEC 60529) 1)

IP66, without shaft seal, on encoder flange sealed (according to IEC 60529) 1)

Permissible relative humidity98 %Operating temperature range–20 °C ... +85 °CStorage temperature range0 °C ... +125 °C, without packageResistance to shocks100 g, 6 ms (according to EN 60068-2-27)Resistance to vibration20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)1) With mating connector inserted.CLASSIFICATIONSECl@ss 5.027270502ECl@ss 5.1.427270502ECl@ss 6.027270590ECl@ss 6.227270590ECl@ss 7.027270502ECl@ss 8.027270502ECl@ss 8.127270502ECl@ss 9.027270502ETIM 5.0EC001486ETIM 6.0EC001486UNSPSC 16.090141112113

Technical Specifications

  • PERFORMANCE
    Max. resolution (number of steps per revolution x number of revolutions)13 bit x 13 bit (8,192 x 8,192)
    Error limits G0.25° 1)
    Repeatability standard deviation σr0.1° 2)
    • 1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.
    • 2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.
  • INTERFACES
    Communication interfacePROFIBUS DP
    Communication Interface detailDPV0
    Data protocolProfile for encoders (07hex) – Class 2
    Address setting0 ... 127, DIP switches or protocol
    Data transmission rate (baud rate)9.6 kBaud ... 12 MBaud, automatic detection
    Status informationLED green (operation), LED red ( bus activity)
    Bus terminationDIP switch 1)
    Initialization time1,250 ms 2)
    Position forming time+ 0.25 ms
    SSI
    Set (electronic adjustment)Via PRESET push button or protocol
    • 1) Should only be connected in the final device.
    • 2) Valid positional data can be read once this time has elapsed.
  • ELECTRICAL DATA
    Connection typeConnection adapter for PROFIBUS 1)
    Supply voltage10 ... 32 V
    MTTFd: mean time to dangerous failure150 years (EN ISO 13849-1) 2)
    • 1) Please order the bus adaptor seperately.
    • 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
  • MECHANICAL DATA
    Mechanical designBlind hollow shaft
    Shaft diameter15 mm 1)
    Weight0.59 kg
    Shaft materialStainless steel
    Flange materialAluminum
    Housing materialAluminum die cast
    Start up torque1.2 Ncm, with shaft seal
    Operating torque0.8 Ncm, with shaft seal
    Permissible shaft movement, axial static/dynamic± 0.5 mm, ± 0.2 mm
    Permissible shaft movement, radial static/dynamic± 0.3 mm, ± 0.1 mm
    Permissible Load capacity of shaft

    300 N / radial

    50 N / axial

    Moment of inertia of the rotor55 gcm²
    Bearing lifetime3.6 x 10^9 revolutions
    Angular acceleration≤ 500,000 rad/s²
    Operating speed≤ 3,000 min⁻¹ 2)
    • 1) Collets for 6, 8, 10, 12, 14 mm and 1/4Inch, 3/8Inch and 1/2Inch as accessories, separate order item. For 15 mm shaft diameter collet is not needed.
    • 2) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
  • AMBIENT DATA
    EMCAccording to EN 61000-6-2 and EN 61000-6-3
    Enclosure rating

    IP67, with shaft seal (according to IEC 60529) 1)

    IP43, without shaft seal, on encoder flange not sealed (according to IEC 60529) 1)

    IP66, without shaft seal, on encoder flange sealed (according to IEC 60529) 1)

    Permissible relative humidity98 %
    Operating temperature range–20 °C ... +85 °C
    Storage temperature range0 °C ... +125 °C, without package
    Resistance to shocks100 g, 6 ms (according to EN 60068-2-27)
    Resistance to vibration20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
    • 1) With mating connector inserted.
  • CLASSIFICATIONS
    ECl@ss 5.027270502
    ECl@ss 5.1.427270502
    ECl@ss 6.027270590
    ECl@ss 6.227270590
    ECl@ss 7.027270502
    ECl@ss 8.027270502
    ECl@ss 8.127270502
    ECl@ss 9.027270502
    ETIM 5.0EC001486
    ETIM 6.0EC001486
    UNSPSC 16.090141112113

Request a Quote

Contact us for pricing and availability

Email Us Contact Form