SIL3 (IEC 61508)
SILCL3 (EN 62061)
CategoryCategory 4 (EN ISO 13849)Performance levelPL e (EN ISO 13849)B10d parameter1.26 x 106 switching cycles (AC-15, 230 V, I = 1.5 A)
5.9 x 106 switching cycles (AC-15, 230 V, I = 0.75 A)
4.35 x 105 switching cycles (DC-13, 24 V, I = 2.5 A)
1 x 107 switching cycles (DC-13, 24 V, I = 0.63 A)
PFHD (mean probability of a dangerous failure per hour)3.0 x 10-8 (EN ISO 13849)TM (mission time)20 years (EN ISO 13849)Stop category0 (EN 60204-1)INTERFACESConnection typeFixed screw terminalsNumber of enabling current paths (N/O)2, relevant for safetyELECTRICAL DATA - OPERATING DATAVoltage supplyA1, A2Output circuit > 25 V AC / 60 V DCPELVOutput circuit ≤ 25 V AC / 60 V DCPELV or SELVSupply voltage VsA1, A224 V AC/DC (20.4 V AC/DC ... 26.4 V AC/DC)Residual ripple≤ 2.4 Vpp 1)Power consumption(≤ 4.6 VA (AC))
(≤ 2.1 W (DC))
Overvoltage categoryIIRated insulation voltage Ui300 V ACRated impulse withstand voltage Uimp4 kVTest voltage2 kV (50 Hz) (EN 60439-1)1) In DC operation, within the limits of VS.ELECTRICAL DATA - CONTROL VOLTAGE: S11, S21, S33Control voltage22 V DC (≥ 17.4 V DC)Control current40 mA ... 100 mAShort-circuit current≤ 300 mA, between S33 / S11 and S21Short-circuit protectionElectronic fuseGalvanized decoupling– (between A1, A2 and S11, S21, S33)ELECTRICAL DATA - INPUT CIRCUITS: S12, S22, S31, S34, S35Input voltageHIGH17.4 V DC ... 26.4 V DCLOW–3 V DC ... 5 V DCInput currentS12, S22, S31≤ 100 mAS34, S35≤ 50 mAReset timeManual≤ 40 msAutomatic≤ 80 msActivation time of reset button≥ 50 msTest pulse width≤ 1,000 µsTest pulse rate≤ 10 HzCable resistance≤ 35 ΩELECTRICAL DATA - OUTPUT CURRENT PATHS: 13/14, 23/24, 31/32, 33/34Response time≤ 25 ms 1)Number of enabling current paths (N/O)2, relevant for safetyNumber of signaling current paths (N/C)1, not safety-relevantContact typePositively drivenContact materialSilver alloy, gold flashedSwitching voltageEnabling current path10 V AC ... 230 V AC10 V DC ... 300 V DCSignaling current path10 V AC ... 230 V AC10 V DC ... 300 V DCCurrent-carrying capacity per OSSDEnabling current path10 mA ... 6 ASignaling current path10 mA ... 6 ATotal current≤ 12 AUsage categoryAC-15/DC-13 (EN 60947-5-1)Rated operating current (voltage)4 A (230 V AC) 360 switching cycles/h
3 A (230 V AC) 3600 switching cycles/h
4 A (24 V DC) 360 switching cycles/h
2.5 A (24 V DC) 3600 switching cycles/h
Switching frequency≤ 3600/hMechanical life (relay contacts)1 x 107 switching cyclesElectrical life (relay contacts)2 x 106 switching cycles1) K1/K2.MECHANICAL DATADimensions (W x H x D)22.5 mm x 114 mm x 96.5 mmWeight0.21 kgCLASSIFICATIONSECl@ss 5.027371990ECl@ss 5.1.427371990ECl@ss 6.027371819ECl@ss 6.227371819ECl@ss 7.027371819ECl@ss 8.027371819ECl@ss 8.127371819ECl@ss 9.027371819ECl@ss 10.027371819ECl@ss 11.027371819ETIM 5.0EC001449ETIM 6.0EC001449ETIM 7.0EC001449UNSPSC 16.090141113704As we supply industrial equipment, product availability and delivery timelines may vary. Once your order is placed, our sales team will contact you within 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.