FEATURESTypeBase unit 1)Dimensions (W x H x D)10.5 mm x 34.6 mm x 71.9 mmHousing design (light emission)RectangularSensing range max.0 m ... 20 m, Through-beam system 2) 3)Sensing range
0 mm ... 1,400 mm, Proximity system 4) 5)
0 m ... 18 m, Through-beam system 2) 3)
Focus6)Type of lightVisible red lightLight sourceLED 7)Angle of dispersionApprox. 65° 6)Wave length650 nmAdjustment
Menu-controlled
Single teach-in button
Delay timeProgrammable, 0 ms ... 9,999 msTime functions
Without time delay
Off delay
On delay
ON and OFF delay
One shot
IndicationDisplayDisplayLED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parametersSpecial features
Parameter (pre-setting)
Anti-interference
1) Up to 15 expansion units can be connected.2) Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).3) LL3-TX01.4) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).5) LL3-DK06.6) See LL3 fiber-optic data.7) Average service life: 100,000 h at TU = +25 °C.MECHANICS/ELECTRONICSSupply voltage12 V DC ... 24 V DC 1)Ripple≤ 10 % 2)Power consumption50 mA 3)Switching outputPNPNumber of switching outputs2Switching modeLight/dark switchingSwitching mode selectorManually selectableOutput current Imax.≤ 100 mAResponse time≤ 16 µs, ≤ 70 µs, ≤ 250 µs, ≤ 2,000 µs, ≤ 8,000 µs 4)Switching frequency
31.2 kHz
7.1 kHz
2 kHz
250 Hz
62.5 Hz
Time functions
Without time delay
Off delay
On delay
ON and OFF delay
One shot
Delay timeProgrammable, 0 ms ... 9,999 msInput-Connection typeMale connector M8, 4-pinCircuit protection
A 5)
B 6)
C 7)
D 8)
Protection classIIIWeight20 gSpecial device✔Housing materialPlastic, ABS/PCEnclosure ratingIP50 9)Items suppliedBEF-WLL180 mounting bracketAmbient operating temperature–25 °C ... +55 °CAmbient storage temperature–40 °C ... +70 °CUL File No.NRKH2.E300503 & NRKH8.E3005031) +- 10%.2) May not exceed or fall below Uv tolerances.3) Without load.4) Selectable.5) A = VS connections reverse-polarity protected.6) B = inputs and output reverse-polarity protected.7) C = interference suppression.8) D = outputs overcurrent and short-circuit protected.9) With correctly attached fibre-optic cable LL3 and closed protection hood.CLASSIFICATIONSECl@ss 5.027270905ECl@ss 5.1.427270905ECl@ss 6.027270905ECl@ss 6.227270905ECl@ss 7.027270905ECl@ss 8.027270905ECl@ss 8.127270905ECl@ss 9.027270905ETIM 5.0EC002651ETIM 6.0EC002651UNSPSC 16.090139121528