■Technical specifications
Mode of operation and design
Measuring principle Electromagnetic with pulsed constant
field
Empty pipe Detection of empty pipe (special
cable required in remote mounted
installation)
Excitation frequency Depend on sensor size
Electrode input impedance > 1 x 1014
Input
Digital input 11 ... 30 V DC, Ri = 4.4 K
• Activation time 50 ms
• Current I11 V DC = 2.5 mA, I30 V DC = 7 mA
Output
Current output
• Signal range 0 ... 20 mA or 4 ... 20 mA
• Load < 800
• Time constant 0.1 … 30 s, adjustable
Digital output
• Frequency 0 ... 10 kHz, 50 % duty cycle
(uni/bidirectional)
• Pulse (active) 24 V DC, 30 mA,
1 K Ri 10 K, short-circuitprotected
(power supplied from
flowmeter)
• Pulse (passive) 3 … 30 V DC, max. 110 mA,
200 Ri 10 K (powered
from connected equipment)
• Time constant 0.1 … 30 s, adjustable
Relay output
• Time constant Changeover relay, same as current
output
• Load 42 V AC/2 A, 24 V DC/1 A
Low flow cut off 0 ... 9.9 % of maximum flow
Galvanic isolation All inputs and outputs are galvanically
isolated.
Max. measuring error (incl. sensor
and zero point)1)
• MAG 5000 0.4 % 1 mm/s
• MAG 6000 0.2 % 1 mm/s
Rated operation conditions
Ambient temperature
• Operation • Display version:
-20 ... +60 °C (-4 ... +140 °F)
• Blind version:
-20 ... +60 °C (-4 ... +140 °F)
• MI-001 version
-25 ... +55 ºC (-13 ... +131 ºF)
• Custody transfer (CT) version
-20 ... +50 ºC (-4 ... +122 ºF)
• Storage -40 ... +70 °C (-40 ... +158 °F)
Mechanical load (vibration)
Compact version 18 ... 1000 Hz, 3.17 g RMS,
sinusoidal in all directions to
IEC 60068-2-36
19“ insert 1 ... 800 Hz, 1 g, sinusoidal in all
directions to IEC 60068-2-36
Degree of protection
Compact version IP67/NEMA 4X/6 to IEC 529 and
DIN 40050 (1 mH2O 30 min.)
19“ insert IP20/NEMA 1 to IEC 529 and
DIN 40050
EMC performance IEC/EN 61326-1 (all environments)
IEC/EN 61326-2-5
Display and keypad
Totalizer Two eight-digit counters for forward,
net or reverse flow
Display Background illumination with
alphanumeric text, 3 x 20 characters
to indicate flow rate, totalized
values, settings and faults;
Reverse flow indicated by negative
sign
Time constant Time constant as current output
time constant
Design
Enclosure material
• Compact version Fiber glass reinforced polyamide;
stainless steel AISI 316/1.4436
(IP65)
• 19Inch insert Standard 19“ insert of aluminum/
steel (DIN 41494), mxwidth:
21 TE, mxheight: 3 HE
• Back of panel IP20/NEMA 1; Aluminum
• Panel mounting IP20/NEMA 1 (prepared for
IP65/NEMA 2 display side);
ABS plastic
• Wall mounting IP66/NEMA 4X; ABS plastic
Dimensions
Compact version See dimensional drawings
19“ insert See dimensional drawings
Weight
Compact version 0.75 kg (2 lb)
19“ insert See dimensional drawings
Power supply • 115 ... 230 V AC +10 % -15 %,
50 ... 60 Hz
• 11 ... 30 V DC or 11 ... 24 V AC
Power consumption • 230 V AC: 17 VA
• 24 VAC: 9 VA, IN = 380 mA,
IST = 8 A (30 ms)
• 12 V DC: 11 W, IN = 920 mA,
IST = 4 A (250 ms)
• 24 V DC: 8.4 VA, IN = 350 mA,
IST = 4 A (10 ms)
IST= 4 A (250 ms):
For solar panel please secure
stable current supply
Certificates and approvals
General purpose • CE (LVD, EMC, PED, RoHS)
• UL (c-UL-us)
Hazardous areas • FM, CSA
- NI Class I Div. 2 Groups A, B,
C, D
Custody transfer • Cold water: MI-001
• Chilled water
- PTB K 7.2 (Germany)
- OE12/C 040 (Austria)
- TS 27.02 008 (Denmark)
Marine
(only for remote version with
MAG 5100 W, DN 50 ... DN 300)
• ABS
• Bureau Veritas
• DNV
• GL
• Lloyd’ s Register of Shipping
Others • CMC/CPA (China)
• C-TICK (Australia and New
Zealand EMC)
• EAC (Russia,Belarus,
Kazakhstan)
• KCC (South Korea)