ALMANYA'dan dünyanın her yerine hızlı teslimat
Geniş Ödeme SeçenekleriBirden fazla ödeme seçeneği
VisaMastercardAmerican ExpressDiners ClubDiscover
  1. Ürünler
  2. Bühler
  3. Prob
  4. Buhler GAS 222.20 Sample Gas Probe

Buhler GAS 222.20 Sample Gas Probe

Technical Documentation

Teknik Veri Sayfaları / Ürün Dokümantasyonları

WhatsApp
Marka
KategoriProb
Ürün AdıBuhler GAS 222.20 Sample Gas Probe
Ürün KoduGAS 222.20
Visa – Secure credit card payment acceptedMastercard – Secure credit card payment acceptedAmerican Express – Secure credit card payment acceptedDiners Club – Secure credit card payment acceptedDiscover – Secure credit card payment accepted

Bizimle iletişime geçin! 24 iş saati içinde (hafta sonu ve tatiller hariç) stok durumunu ve tahmini teslim süresini bildiriyoruz.

Ürün Açıklaması

Bühler markalı Buhler GAS 222.20 Sample Gas Probe ürünleri, paralel ithalat yöntemi ile ülkenize temin edilmektedir. İmtek Mühendislik olarak, orijinal Bühler ürünlerini rekabetçi fiyatlar ve hızlı teslimat seçenekleriyle müşterilerimize ulaştırmaktayız. Web sitemizde Buhler GAS 222.20 Sample Gas Probe ürün kodu yer almasa dahi, Bühler ürün gamına ait tüm kalemler için fiyat teklifi talebinde bulunabilirsiniz; ekibimiz en kısa sürede teklifinizi hazırlayacaktır.

Sample Gas Probe
  • Heated, temperature adjustable up to 200 °C / 392 °F
  • 115/230 V
  • Base unit
  • With weather hood
  • Heater with electronic regulator
  • Limit outputs
  • Insulation
  • Including flange seal and screws

Sample gas probe with weather protection, temperature adjustable heater, and integrated particle filter. For applications with low dust load. The filter can be replaced without tools.

GAS 222.21 Flow chart
Technical Data Gas Probe Technical Data Probe operating temperature:
max. 200 °C
Ambient temperature without accessories:
-20 to +70 °C
Ambient temperature with accessories:
Component
Ambient temperature range
Compressed air valve:
-10 °C < Tamb < +55 °C
Pneumatic drive:
-20 °C < Tamb < +80 °C
Limit switch:
-20 °C < Tamb < +100 °C
Solenoid valve for pneumatic drive:
-10 °C < Tamb < +55 °C
Component
Medium temperature range
Compressed air valve:
-10 °C to +80 °C
Solenoid valve for pneumatic drive:
-10 °C to +100 °C
Medium temperature (blowback):
Regulator setting range:
+50 to +200 °C
Low/high temperature alarm:
Alarm adjustable ±5.....30 K from setpoint, factory preset to 15 K, max. switching
current 1 A
Electrical data:
230 V, 2.0 A, 50/60 Hz 115 V, 3.8 A, 50/60 Hz
Protection class:
IP54
Max. operating pressure:
6 bar
Materials in contact with media Flange:
Probe body:
Ball valve:
Seal:
Stainless steel 1.4571 Stainless steel 1.4571 Stainless steel 1.4408/1.4462/PTFE
Stainless steel 1.4404/graphite/and see filter Optional coating with SilcoNert® 2000 *
*The SilcoNert® 2000 coating forms a layer of hydrogenated, amorphous silicon on the surfaces of the measuring gas probe that
are in contact with media. It is applied by chemical vapour deposition (CVD), which creates a uniformly thin layer on the surface.
SilcoNert® 2000 is temperature-resistant up to 400 °C, chemically inert and hydrophobic. The coating is resistant to many chemically corrosive liquids. If you are unsure about the suitability for specific gas matrices, please contact Bühler Technologies
GmbH.
2
Bühler Technologies GmbH
We reserve the right to amend specification.
DE461021 ◦ 01/2026

Sık Sorulan Sorular

Buhler GAS 222.20 Sample Gas Probe (Bühler) ürünü hakkında sıkça sorulan sorular aşağıda yer almaktadır. Bühler markasına ait Buhler GAS 222.20 Sample Gas Probe ürününü United States temin etmenize yardımcı olmaktan memnuniyet duyarız.

İmtek Mühendislik, Bühler ürünlerini güvenilir kaynaklardan temin ederek United States orijinal ve kaliteli Bühler ekipmanlarını rekabetçi fiyatlarla sunmaktadır.