Applications
Machine tools, HVAC, Refrigeration, Water treatment, Process technology
Category
Test benches
Accuracy @ 25°C typ.
± 0.5 % FS typ.
Dielectric strength
100 VAC, 50 Hz
Measuring principle
Thick-film-on-ceramic
Vibration
10 g (10 ... 2000 Hz)
NLH @ 25°C (BSL) typ.
± 0.2 % FS typ.
Pressure connections
G1/4" f; G1/4" m;
G1/2" m, DIN3852-E;
1/4"NPT m;
R1/4" m, DIN3858;
7/16"-20UNF m, DIN3866;
7/16"-20UNF m, SAE4 (J1926);
7/16"-20UNF f, SAE J512, valve opener;
G3/4" frontal membrane
Media temperature
-25°C ... +85°C
Shock
50 g / 3 ms
Electrical connections
Male electrical plug M12x1, 5-pole; Male electrical plug M12x1, 4-pole
Long term stability 1 year typ.
± 0.3 % FS typ.
Ambient temperature
-25°C ... +85°C
Protection
IP67
Output signal
4 ... 20 mA, 0 ... 5 VDC, 1 ... 6 VDC,
0 ... 10 VDC, switchable mA or V
TEB typ. @ -25 ... +85°C
± 2.0 % FS typ.
Measuring range
0 ... 0.2 to 0 ... 100 bar
0 ... 2.5 to 0 ... 1500 psi
adjustable