Applications
Machine tools, Hydraulics, Water treatment
Category
Accuracy @ 25°C typ.
± 0.5 % FS typ.
Dielectric strength
Type 14/16/17/23: 100 VAC, 50 Hz
Type 19: 250 VAC, 50 Hz
Measuring principle
Thick-film-on-ceramic
Vibration
4 g (10...2000 Hz)
NLH @ 25°C (BSL) typ.
± 0.2 % FS typ.
Pressure connections
G1/4" f; G1/4" m;
G1/2" m, DIN3852-A;
G1/2" m, DIN3852-E;
G1/2" m, DIN3852-E, with inner cone;
1/4"NPT m, ANSI B1.20.1;
1/8"NPT m, ANSI B1.20.1;
7/16"-20UNF m, SAE4 (J1926);
7/16”-20UNF m, DIN3866;
7/16”-20UNF f, SAE J512,
Media temperature
-25°C ... +125°C
400 bar/5000 psi: -10°C ... +125°C
Shock
50 g / 8 ms
Electrical connections
EN175301-803-A (DIN43650-A); M12x1; Industrial standard, contact distance 9.4 mm; Packard Metri Pack; Cable
Long term stability 1 year typ.
± 0.3 % FS typ.
Ambient temperature
-25°C ... +125°C
Cable PVC 22: -5°C ... +60°C
Cable PUR 24: -20°C ... +70°C
Cable Raychem 08: -20°C ... +100°C
Protection
IP65, IP67, IP68
Output signal
4 ... 20 mA, 0 ... 5 VDC, 1 ... 6 VDC,
0 ... 10 VDC, 0.5 ... 4.5 VDC ratiom.
TEB typ. @ -25 ... +85°C
± 3.0 % FS typ.
Measuring range
0 ... 1 to 0 ... 400 bar
0 ... 15 to 0 ... 5000 psi