Applications
Machine tools, Hydraulics, Industrial applications
Category
Water treatment
Accuracy @ 25°C typ.
± 0.5 % FS typ.
± 0.3 % FS typ.
Dielectric strength
50 VAC, 50 Hz
Measuring principle
Thin-film-on-steel
Vibration
15 g RMS (20...2000 Hz) acc.to EN 60068-2-64
25 g sin (80...2000 Hz), 1 oct./min, (1x @ 25°C) acc.to EN 60068-2-6
NLH @ 25°C (BSL) typ.
± 0.2 % FS typ.
Pressure connections
G1/4" f; G1/4" m Seal;
G1/4" m (Manometer) EN 837;
G1/2" m (Manometer) EN 837;
1/4"NPT m; 1/4"- 18 NPT f; 1/2"NPT m;
R1/4" m, DIN3858;
M14x1.5 m, DIN6149-2;
7/16"-20UNF m, DIN3866;
7/16"-20UNF m, SAE4 (J1926);
7/16"-20UNF f
Media temperature
–40°C ... +125°C
Shock
500 g / 1 ms acc.to EN 60068-2-27
Electrical connections
EN175301-803-A (DIN43650-A); M12x1; Industrial standard, contact distance 9.4 mm; Packard Metri Pack; MIL-C 26482; DIN72585; cable
Long term stability 1 year typ.
< ± 0.1 % FS typ.
Ambient temperature
–40°C ... +125°C
Cable PVC: -5°C ... +60°C
Cable PUR: -20°C ... +70°C
Cable Raychem: -20°C ... +100°C
Protection
IP65, IP67, IP68
Output signal
4 ... 20 mA, 0 ... 5 VDC, 1 ... 6 VDC,
0 ... 10 VDC, 0.5 … 4.5 VDC ratiometric
TEB typ. @ -25 ... +85°C
± 1.75 % FS typ.
Measuring range
0 ... 0.2 to 0 ... 600 bar
0 ... 3 to 0 ... 7500 psi