Applications
Shipbuilding, Ex Zones 0, 1, 2 (gas); 20, 21, 22 (dust) and mining, Hydrogen
Category
Potentially hazardous areas
Accuracy @ 25°C typ.
± 0.5 % FS typ.
± 0.3 % FS typ.
Dielectric strength
500 VAC, 50 Hz
Measuring principle
Thin-film-on-steel
Approval / conformity
DNV-GL, KRS, RMRS
ATEX / IECEx, according to the norm
EN/IEC 60079-0/EN 60079-11/
EN 60079-26/ EN 50303
Vibration
10 g (50...2000 Hz)
NLH @ 25°C (BSL) typ.
± 0.2 % FS typ.
± 0.1 % FS typ.
Pressure connections
G1/4" m;
G1/4" m (Manometer) EN 837;
G1/4" f;
G1/2" m;
G1/2" m (Manometer) EN 837;
R1/4" m;
1/4"NPT m;
M18x1.5 m
Media temperature
Max. –40°C ... +120°C
(see electrical connection)
Shock
50 g / 3 ms
Electrical connections
EN175301-803-A; M12x1; MIL-C 26482; Binder 723; Cable
Long term stability 1 year typ.
± 0.2 % FS typ.
± 0.2 % FS typ.
Ambient temperature
Max. –40°C ... +120°C
(see electrical connection)
Protection
Min. IP65
Electrical connection cable: IP67
Electrical connection 02: IP67
Output signal
4 ... 20 mA
TEB typ. @ -25 ... +85°C
± 2.0 % FS typ.
± 0.5 % FS typ.
Measuring range
0 ... 0.4 to 0 ... 2000 bar
0 ... 5 to 0 ... 30000 psi