Applications
Machine tools, Hydraulics, HVAC, Refrigeration, Process technology, Water treatment
Category
Hydraulic
Accuracy @ 25°C typ.
± 0.5 % FS typ.
Dielectric strength
50 VAC, 50 Hz
Measuring principle
Thin-film-on-steel
Vibration
15 g RMS (20...2000 Hz) (EN60068-2-64)
25 g sin (80...2000 Hz), 1 oct./min, (1x @ 25°C) (EN60068-2-6)
NLH @ 25°C (BSL) typ.
± 0.2 % FS typ.
Pressure connections
G1/4" m; G1/4" m (Manometer);
G1/8" m, DIN3852-E;
1/4"NPT m; 1/4"NPT f; 1/8"NPT m;
7/16"-20UNF f, SAE J512;
7/16"-20UNF m, SAE4 (J1926);
7/16"-20UNF m, DIN3866;
9/16"-18UNF m, SAE6 (J1926);
R1/4" m, DIN3858;
R1/4" m, DIN299
Media temperature
–40°C ... +125°C
Shock
50 g / 11 ms
100 g / 6 ms Male electrical plug M12x1 (EN60068-2-27) 2)
Electrical connections
Industrial standard, contact distance 9.4 mm; M12x1; MIL-C 26482; Deutsch DT04-3P/4P; cable
Long term stability 1 year typ.
< ± 0.1 % FS typ.
Ambient temperature
–40°C ... +125°C
(Cable PVC 22: -5°C ... +60°C)
(Cable PUR 24: -40°C ... +70°C)
(Cable Radox Tenuis 88: -40°C ... +100°C)
Protection
IP65, IP67, IP68
Output signal
4 ... 20 mA, 0.5 ... 4.5 VDC, 0 ... 5 VDC, 0.5 ... 5 VDC, 1 ... 5 VDC, 0.5 ... 5.5 VDC, 1 ... 6 VDC, 0 ... 10 VDC, 1 ... 10 VDC, 0.1 ... 10.1 VDC, 0.5 ... 4.5 VDC ratiometric,
Switching output: 1 or 2 PNP transistors
TEB typ. @ -25 ... +85°C
± 1.75 % FS typ.
Measuring range
0 ... 2.5 to 0 ... 600 bar
0 ... 30 to 0 ... 7500 psi