Applications
Shipbuilding, Engine manufacturing, Railways, Machine tools, Hydraulics
Category
Dielectric strength
(IEC/EN 60730-1)
>1.5 kV AC/60 s terminal ground
>500 VAC/60 s via open contacts
Measuring principle
Membrane
Approval / conformity
ABS, BV, CCS, DNV-GL, KRS, LRS, RINA,
EN60730-1/ EN60730-2-6: Typ 2.B.H
Vibration
Switch IEC/EN 60068-2-6:
10...59 Hz: ±0.75 mm Ampl.
59...500 Hz: 5 g
Pressure connections
G1/8" f, G1/4" f, M10x1.0 f
Media temperature
0°C ... +80°C
Shock
50 g / 3 ms
Electrical connections
EN175301-803-A (DIN43650-A)
Ambient temperature
0°C ... +80°C
Sensor
See ordering information
Protection
IP65
Output signal
1 Floating change-over contact (SPDT)
Measuring range
1 ... 10 to 10 ... 100 bar
14 ... 150 to 150 ... 1500 psi