Varec NMR81 Radar Tank Gauge


Varec NMR81   Radar Tank Gauge Image

Are you interested in the product Varec NMR81 Radar Tank Gauge from manufacturer Varec with code NMR81? Contact us now and get offer. Imtek Engineering, the fastest and most reliable industrial equipment supplier in the world, will offer you the best offer!

Get Offer With E-Mail: info@im-tek.com
Get a offer for Varec NMR81 Radar Tank Gauge from our live support team now!

The NMR81 Radar Tank Gauge (RTG), with an accuracy rate of ±0.5 mm, is an intelligent level radar tank gauge designed for high accuracy liquid level measurement in storage and process applications.SpecificationsWeight Housing with electronics: approx. 12 kg (26 lbs) Sensor and processor connections: 6 to 36 kg (13 to 80 lb); dependent on the device version Enclosure Housing: Aluminum Antenna and Process Connection: • 316L: Shaft and flange • PTFE: Antenna lens • FKM/HNBR/FFKM: Seal Rated IP66/68, NEMA Type 4x/6P enclosure Temperature Ambient: Device: -40 to +60°C (-40 to +140°F) Display Module: -20 to +70°C (-4 to +158°F) Process: -40 to +200°C (-40 to +392°F) Primary Output MODBUS RS485 V1 4-20mA HART Ex d/XP, RTD input 4-20mA HART Ex i/IS, RTD input Range Calibration Range: 30 m (98 ft) Maximum Range: Depending upon configuration choices – 70 m (230 ft) For calibration to regulatory standards – 30 m (98 ft) Approvals FM, IEC Ex, ATEX and EACOptionsApprovals & Certifications FM, IEC Ex,  ATEX and EAC approvals SIL2 and SIL 3 certifications Power Supply High voltage type: 85 to 264 VAC, 50/ 60 Hz, 28.8 VA Low voltage type: In preparation Communication Primary Output Modbus RS485 V1 4-20mA HART Ex d/XP, RTD input 4-20mA HART Ex i/IS, RTD input Secondary I/O Analogue 1 x “Ex d/XP 4-20mA HART + RTD input” 2 x “Ex d/XP 4-20mA HART + RTD input” 1 x “Ex i/IS 4-20mA HART+ RTD input” 2 x “Ex i/IS 4-20mA HART+ RTD input” 1 x “Ex i/IS 4-20mA HART + RTD input” 1 x “Ex d/XP 4-20mA HART + RTD input” None Secondary I/O Exd 1 x “2x relay + 2x discrete I/O” 2 x “2x relay + 2x discrete I/O” 3 x “2x relay + 2x discrete I/O” 1x “MODBUS RS485” 1x “MODBUS RS485”, 1 x “2x relay + 2x discrete I/O” 1x “MODBUS RS485”, 2 x “2x relay + 2x discrete I/O” None The HART Ex ia/IS active input is available by default. It needs not to be chosen explicitly when ordering a device. Antenna Lens antenna – 50mm/2?, 80mm/3?, 100mm/4? Flange Type NPS ASME B16.5, 150 lb, 2? to 10? NPS ASME B16.5, 300 lb, 2? to 6? PN10/16, DN50 to DN250 PN25/PN40, DN50 to DN150 UNI flange DN150/6?/150, max PN1/Cl.14.5/1K, suitable for DN150 PN10/16, NPS 6? Cl.150, 10K 150 UNI flange DN200/8?/200, max PN1/Cl.14.5/1K, suitable for DN200 PN10/16, NPS 8? Cl.150, 10K 200 UNI flange DN250/10?/250, max PN1/Cl.14.5/1K, suitable for DN250 PN10/16, NPS 10? Cl.150, 10K 250 Programming Local display; operation via the local display is possible without opening the device Configuration software (e.g. DeviceCare); connected via: – HART – Service port (CDI) with optional Commubox FXA291