Features
Control sensitivity of .125" (.32 cm) water column allows use in precision processes.Pressure balanced supply valve prevents supply pressure changes from affecting the setpoint.Optional check valve permits dumping of downstream pressure when supply is opened to atmosphere.Separate control chamber isolates the diaphragm from the main flow to eliminate hunting and buzzing.An aspirator tube compensates downstream pressure droop under flow conditions.
Specifications
Supply Pressure
500 PSIG, (35.0 bar), (3500 kPa) Maximum
Flow Capacity
40 SCFM (68 m3/HR) @ 100 PSIG, (7.0 bar), (700 kPa) Supply and 20 PSIG, (1.5 bar), (150 kPa) Setpoint
Exhaust Capacity
5.5 SCFM (9.35 m /HR) where Downstream Pressure is 5 PSIG, (.35 bar), (35 kPa) above 20 PSIG, (1.5 bar), (150 kPa) Setpoint
Supply Pressure Effect
Less than 0.1 PSIG, (.007 bar), (.7 kPa) for 100 PSIG, (7.0 bar), (700 kPa) change in Supply Pressure
Sensitivity
.125" (.005 PSIG) (.32 cm) Water Column
Ambient Temperature
-40°F to +200°F, (-40°C to 93°C)