Wiring Code Cable length 3m with free cable end
excitation voltage +
(+EX)
brown
supply voltage +
(UB)
brown
shield signal +
(SHI)
black green
shield
(SHI)
black
(+SI)
excitation voltage -
(-EX)
yellow
signal -
(-SI)
white
Compressive load is positive change of signal.
signal +
(OUT)
green
ground / signal -
(0V)
yellow
programming interface
(PRG)
white
with integrated amplifier (0V and PRG to be connected by the customer) With integrated amplifier
(0V and PRG to be connected by the customer)
Specification Accuracy Class
% Fnom
Rated force (Fnom) Maximum operating force (FG) Breaking force (FB) Lateral force limit (FQ)
kN % Fnom % Fnom % Fnom
0.05/ 0.1/ 0.2/ 0.5/ 1/ 2/ 5/ 10 150 > 300 100
Rated characteristic value (Cnom) Relative deviation of zero signal Reference excitation voltage (Uref)
Input resistance (Re) Output resistance (Ra) Insulation resistance (Ris)
mV/V % VDC Ω Ω Ω
2.000 ± 0.002 ≤1 10 380 ± 30 352 ± 1.5 > 5 x 109
Relative linearity error (dlin) 1) Relative reversibility error (v)1) Temperature effect on zero signal (TK0)
Temperature effect on characterist. value (TKC)
TK output signal under load Relative creep over 30 minutes (dcr, F+E) Tolerance of output signal
Tolerance of zero signal
% % %/10K %/10K %/10K % % %
Reference temperature (Tref) Rated temperature range (BT, nom) Operating temperature range (BT, G)
Storage temperature range (BT, S) Environmental protection (EN 60529)
C C o C o C o o
Supply voltage Input current Output signal for compression force (0...FN)
Alternatively:
- Voltage output (max. load: 5mA)
- Current output (max. resistance) Output signal for tension or pressure force (-FN ...FN)
- Voltage output
0.1
0.05
≤ 0.1 ≤ 0.1 ≤ 0.05 ≤ 0.10
≤ 0.05 ≤ 0.05 ≤ 0.025 ≤ 0.05
≤ 0.10
≤ 0.05
0.21) with Integrated Amplifier 0.05/ 0.1/ 0.2/ 0.5/ 1/ 2/ 5/ 10 150 > 300
100
0.1 0.2 0.1 0.2 0.1 ≤1
+23 -20 ... +60 -30 ... +70 -40 ... +70
IP 67
+23 -20 ... +60 -30 ... +70 -40 ... +70
IP 67
VDC mA
19 ... 28 35 (at 24V)
V mA
0 ... 10 4 ... 20 (300 Ω)
V
All data according to VDI/VDE/DKD 2638
-10 ... +10
1) Accuracy class 0.1% on request
Order Example Type Code
Description
KAB-E/1kN/0.2/24V/0 ...10V
Force transducer 1kN with 0.2% accuracy and integrated amplifier Output signal
Supply voltage Accuracy class Rated force E = Integrated amplifier Model
Options Typschlüssel
Bezeichnung
ATEX-Certificate
KAB-EX
for 100N, 200N, 500N, 1kN, 2kN, 5kN, 10kN. Please not ATEX data sheet!
CANopen interface
KAB-DI
for 50N bis 10kN, Please note data sheet „Force Transducer with CANopen Interface“!
2
excitation voltage +
(+EX)
brown
supply voltage +
(UB)
brown
shield signal +
(SHI)
black green
shield
(SHI)
black
(+SI)
excitation voltage -
(-EX)
yellow
signal -
(-SI)
white
Compressive load is positive change of signal.
signal +
(OUT)
green
ground / signal -
(0V)
yellow
programming interface
(PRG)
white
with integrated amplifier (0V and PRG to be connected by the customer) With integrated amplifier
(0V and PRG to be connected by the customer)
Specification Accuracy Class
% Fnom
Rated force (Fnom) Maximum operating force (FG) Breaking force (FB) Lateral force limit (FQ)
kN % Fnom % Fnom % Fnom
0.05/ 0.1/ 0.2/ 0.5/ 1/ 2/ 5/ 10 150 > 300 100
Rated characteristic value (Cnom) Relative deviation of zero signal Reference excitation voltage (Uref)
Input resistance (Re) Output resistance (Ra) Insulation resistance (Ris)
mV/V % VDC Ω Ω Ω
2.000 ± 0.002 ≤1 10 380 ± 30 352 ± 1.5 > 5 x 109
Relative linearity error (dlin) 1) Relative reversibility error (v)1) Temperature effect on zero signal (TK0)
Temperature effect on characterist. value (TKC)
TK output signal under load Relative creep over 30 minutes (dcr, F+E) Tolerance of output signal
Tolerance of zero signal
% % %/10K %/10K %/10K % % %
Reference temperature (Tref) Rated temperature range (BT, nom) Operating temperature range (BT, G)
Storage temperature range (BT, S) Environmental protection (EN 60529)
C C o C o C o o
Supply voltage Input current Output signal for compression force (0...FN)
Alternatively:
- Voltage output (max. load: 5mA)
- Current output (max. resistance) Output signal for tension or pressure force (-FN ...FN)
- Voltage output
0.1
0.05
≤ 0.1 ≤ 0.1 ≤ 0.05 ≤ 0.10
≤ 0.05 ≤ 0.05 ≤ 0.025 ≤ 0.05
≤ 0.10
≤ 0.05
0.21) with Integrated Amplifier 0.05/ 0.1/ 0.2/ 0.5/ 1/ 2/ 5/ 10 150 > 300
100
0.1 0.2 0.1 0.2 0.1 ≤1
+23 -20 ... +60 -30 ... +70 -40 ... +70
IP 67
+23 -20 ... +60 -30 ... +70 -40 ... +70
IP 67
VDC mA
19 ... 28 35 (at 24V)
V mA
0 ... 10 4 ... 20 (300 Ω)
V
All data according to VDI/VDE/DKD 2638
-10 ... +10
1) Accuracy class 0.1% on request
Order Example Type Code
Description
KAB-E/1kN/0.2/24V/0 ...10V
Force transducer 1kN with 0.2% accuracy and integrated amplifier Output signal
Supply voltage Accuracy class Rated force E = Integrated amplifier Model
Options Typschlüssel
Bezeichnung
ATEX-Certificate
KAB-EX
for 100N, 200N, 500N, 1kN, 2kN, 5kN, 10kN. Please not ATEX data sheet!
CANopen interface
KAB-DI
for 50N bis 10kN, Please note data sheet „Force Transducer with CANopen Interface“!
2
常见问题
关于AST品牌AST KAB-E/10kN/0,2/24V/4...20mA Sensor产品的常见问题。Imtek Engineering随时准备帮助您在United States采购AST的AST KAB-E/10kN/0,2/24V/4...20mA Sensor。
Imtek Engineering通过可信赖的供应渠道采购正品AST产品,并以具有竞争力的价格向United States客户提供。