自2001年起提供工业备件与工程解决方案。
德国仓直发,全球快速配送
多种支付方式多种付款选项
Atos X-MAP-320 Pressure Switch
产品描述
Atos的产品(包括Atos X-MAP-320 Pressure Switch)通过平行进口渠道采购,并快速可靠地交付给United States的客户。Imtek Engineering以具有竞争力的价格提供正品Atos零部件。即使Atos X-MAP-320 Pressure Switch未在我们的网站上列出,您也可以随时申请报价——我们的团队将迅速响应并为您提供专属报价。
Table
D250-4/E
Pressure switches type MAP with fixed switching pressure differential and microswitch with gold plated contacts
MAP are hydro-electric pressure switches with fixed switching pressure differential.
The mechanical microswitch with gold plated contacts grants high reliability and
long life service.
The microswitch changes its status when the pressure in the hydraulic circuit reaches the switching value set on the adjusting knob.The microswitch returns to the
original rest position when the pressure in the hydraulic circuit drops below the
nominal fixed switching pressure differential (hysteresis). The electric connector
provides both NC or NO contacts.
The pressure in the circuit operates the piston a acting against the adjustable
spring b ; once the pressure setting is reached, the piston f actuates the
microswitch c.
The pressure switching value is selectable by a graduated adjusting knob d.
a Servo-piston b Spring c Microswitch with gold plated contacts
d Adjusting knob with graduated scale
e Body f Switch actuator g Adjusting knob locking srew h Electric connector type 664
Clockwise rotation increases the setting pressure.
(included in the supply)
1
Max pressure: 630 bar
MODEL CODE
-
MAP
160
/
E
/
**
Fixed differential pressure switch Pressure range:
40 = 5 ÷ 40 bar 80 = 7÷ 80 bar
2
Series number
160 = 10 ÷ 160 bar 320 = 30 ÷ 320 bar 630 = 50 ÷ 630 bar
* Seals material, see section 2:
= NBR
PE = FKM
BT = HNBR
Options:
E = Common electric contact connected to pin 1, see section 3
MAIN CHARACTERISTICS, SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
Assembly position / location
Any position
Subplate surface finishing
Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
CE to Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU as last update by 2015/65/EU
REACH Regulation (EC) n°1907/2006 Standard = -30°C ÷ +70°C /PE option = -20°C ÷ +70°C
Compliance Ambient temperature
/BT option = -40°C ÷ +70°C
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option)= -20°C ÷ +80°C
HNBR seals (/BT option)= -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Seals, recommended fluid temperature Recommended viscosity
15÷100 mm2/s - max allowed range 2.8 ÷ 500 mm2/s
Fluid contamination class
ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β25 >
_ 75 recommended)
Hydraulic fluid
Suitable seals type
Classification
Ref. Standard
NBR, FKM, HNBR
HL, HLP, HLPD, HVLP, HVLPD
DIN 51524
FKM
HFDU, HFDR
NBR, HNBR
HFC
Mineral oils Flame resistant without water Flame resistant with water
3
ISO 12922
CHARACTERISTICS AND WIRING OF INTERNAL MICROSWITCH 125 AC
Max current resistive load Max current inductive load (Cos ϕ = 0,4) Insulating resistance
[A] [A]
Supply voltage [V] 250 AC 30 DC
Rest position
Pressure operated position
250 DC
7
5
5
0,2
4
2
3
0,02
STD
≥100MΩ
Contact resistance
15 mΩ
Electrical life-expectancy
≥1.000.000 switchings
Mechanical life-expectancy
≥10.000.000 switchings
/E
D250
D250-4/E
Pressure switches type MAP with fixed switching pressure differential and microswitch with gold plated contacts
MAP are hydro-electric pressure switches with fixed switching pressure differential.
The mechanical microswitch with gold plated contacts grants high reliability and
long life service.
The microswitch changes its status when the pressure in the hydraulic circuit reaches the switching value set on the adjusting knob.The microswitch returns to the
original rest position when the pressure in the hydraulic circuit drops below the
nominal fixed switching pressure differential (hysteresis). The electric connector
provides both NC or NO contacts.
The pressure in the circuit operates the piston a acting against the adjustable
spring b ; once the pressure setting is reached, the piston f actuates the
microswitch c.
The pressure switching value is selectable by a graduated adjusting knob d.
a Servo-piston b Spring c Microswitch with gold plated contacts
d Adjusting knob with graduated scale
e Body f Switch actuator g Adjusting knob locking srew h Electric connector type 664
Clockwise rotation increases the setting pressure.
(included in the supply)
1
Max pressure: 630 bar
MODEL CODE
-
MAP
160
/
E
/
**
Fixed differential pressure switch Pressure range:
40 = 5 ÷ 40 bar 80 = 7÷ 80 bar
2
Series number
160 = 10 ÷ 160 bar 320 = 30 ÷ 320 bar 630 = 50 ÷ 630 bar
* Seals material, see section 2:
= NBR
PE = FKM
BT = HNBR
Options:
E = Common electric contact connected to pin 1, see section 3
MAIN CHARACTERISTICS, SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
Assembly position / location
Any position
Subplate surface finishing
Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
CE to Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU as last update by 2015/65/EU
REACH Regulation (EC) n°1907/2006 Standard = -30°C ÷ +70°C /PE option = -20°C ÷ +70°C
Compliance Ambient temperature
/BT option = -40°C ÷ +70°C
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
FKM seals (/PE option)= -20°C ÷ +80°C
HNBR seals (/BT option)= -40°C ÷ +60°C, with HFC hydraulic fluids = -40°C ÷ +50°C
Seals, recommended fluid temperature Recommended viscosity
15÷100 mm2/s - max allowed range 2.8 ÷ 500 mm2/s
Fluid contamination class
ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 μm (β25 >
_ 75 recommended)
Hydraulic fluid
Suitable seals type
Classification
Ref. Standard
NBR, FKM, HNBR
HL, HLP, HLPD, HVLP, HVLPD
DIN 51524
FKM
HFDU, HFDR
NBR, HNBR
HFC
Mineral oils Flame resistant without water Flame resistant with water
3
ISO 12922
CHARACTERISTICS AND WIRING OF INTERNAL MICROSWITCH 125 AC
Max current resistive load Max current inductive load (Cos ϕ = 0,4) Insulating resistance
[A] [A]
Supply voltage [V] 250 AC 30 DC
Rest position
Pressure operated position
250 DC
7
5
5
0,2
4
2
3
0,02
STD
≥100MΩ
Contact resistance
15 mΩ
Electrical life-expectancy
≥1.000.000 switchings
Mechanical life-expectancy
≥10.000.000 switchings
/E
D250
常见问题
关于Atos品牌Atos X-MAP-320 Pressure Switch产品的常见问题。Imtek Engineering随时准备帮助您在United States采购Atos的Atos X-MAP-320 Pressure Switch。
Imtek Engineering通过可信赖的供应渠道采购正品Atos产品,并以具有竞争力的价格向United States客户提供。