Cemb
Cemb T5-LVDT Absolute Expantion Sensor
Product Code:T5-LVDT
Description
The transducer T5-LVDT is used for performing the measurement of Absolute Displacement.
Range of measurement0 to 50 mmSensitivity0,4 V/mmCompositionSensor T5-LVDT/50Adapter AD1-BOXTransformer LVDTImpedance, primary winding = 600 ohm/2500 HzImpedance, secondary windings = 800 ohm/2500Max linearity error = ± 0.5% f.s.Nominal sensitivity = 34 mV/0.001”/VFrequency range = 50 Hz to 10 kHzSupply voltage = 3 V rms (rated)Range of applicationTemperature = -55°C to +95°CHumidity = max 95% not condensingVibrations = max 20 g / 2 KHzAmbient = IP55 EN 60529/10.91 standardsMaintenancenonePower supplyTransducer = +15 Vdc, GND - Adapter = +15 to +24 Vdc, GNDOuter casing materialAluminiumTechnical Specifications
The transducer T5-LVDT is used for performing the measurement of Absolute Displacement.
| Range of measurement | 0 to 50 mm |
| Sensitivity | 0,4 V/mm |
| Composition | Sensor T5-LVDT/50 |
| Adapter AD1-BOX | |
| Transformer LVDT | Impedance, primary winding = 600 ohm/2500 Hz |
| Impedance, secondary windings = 800 ohm/2500 | |
| Max linearity error = ± 0.5% f.s. | |
| Nominal sensitivity = 34 mV/0.001”/V | |
| Frequency range = 50 Hz to 10 kHz | |
| Supply voltage = 3 V rms (rated) | |
| Range of application | Temperature = -55°C to +95°C |
| Humidity = max 95% not condensing | |
| Vibrations = max 20 g / 2 KHz | |
| Ambient = IP55 EN 60529/10.91 standards | |
| Maintenance | none |
| Power supply | Transducer = +15 Vdc, GND - Adapter = +15 to +24 Vdc, GND |
| Outer casing material | Aluminium |