自2001年起提供工业备件与工程解决方案。
德国仓直发,全球快速配送
多种支付方式多种付款选项
Ropex RES-430 Temperature Controller
产品描述
Ropex的产品(包括Ropex RES-430 Temperature Controller)通过平行进口渠道采购,并快速可靠地交付给United States的客户。Imtek Engineering以具有竞争力的价格提供正品Ropex零部件。即使Ropex RES-430 Temperature Controller未在我们的网站上列出,您也可以随时申请报价——我们的团队将迅速响应并为您提供专属报价。
Temperature Controller
Technical data
6
Technical data
Type of construction
RES-430 motherboard with power section:
Open design for installation in the machine frame Dimensions (L x W): 210 x 110mm, height: 45mm (incl. terminals)
T-430 display terminal:
For installation in the machine frame Dimensions (W x H): 144 x 72mm; depth: 66mm (incl. connecting cables)
Line voltage
As of software revision 102:
115VAC version: 110VAC -15%…120VAC +10% (equivalent to 94…132VAC) 230VAC version: 220VAC -15%…240VAC +10% (equivalent to 187…264VAC)
Up to software revision 101:
115VAC, 230VAC, tolerance: +10% / -15% depending on device version ( section 13 "How to order" on page 66)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Heatsealing band type and temperature range
Several different ranges can be selected on the controller in the Configuration menu:
Default: Temperature coefficient 1100ppm (Alloy A20), 0…300°C
Heatsealing band voltage (secondary voltage of impulse transformer)
12…42VAC
Max. load current (max. secondary current of impulse transformer) Terminals 5, 6, 7, 8
Two heatsealing bands:
One heatsealing band:
Min. load current
Up to SW revision 007:
SW revision 008 or higher:
Analog output (actual value) Terminals 10+11
0…10V DC, Imax = 5mA Equivalent to 0…300°C or 0…500°C Accuracy: ±1% add. 50mV
Isec max = 90A (per heatsealing band: Imax = 45A) Isec max = 70A
If only one heatsealing band is used, terminals 7+8 must be externally jumpered with a high current cable in order to
avoid malfunctions or damage to the controller.
!
Isec min = 30A Isec min = 20A
Motherboard and display terminal (with same serial number) are aligned on each other during production (before first delivery). When
using components with different serial numbers together the analogue output has higher tolerances.
!
START with contact Terminals 12+14
Switching threshold: 3.5VDC, Umax = 5VDC, Imax = 5mA
FOOT SWITCH with contact Terminals 12+13
Switching threshold: 3.5VDC, Umax = 5VDC, Imax = 5mA
Version 1
RES-430
Page 11
6
Technical data
Type of construction
RES-430 motherboard with power section:
Open design for installation in the machine frame Dimensions (L x W): 210 x 110mm, height: 45mm (incl. terminals)
T-430 display terminal:
For installation in the machine frame Dimensions (W x H): 144 x 72mm; depth: 66mm (incl. connecting cables)
Line voltage
As of software revision 102:
115VAC version: 110VAC -15%…120VAC +10% (equivalent to 94…132VAC) 230VAC version: 220VAC -15%…240VAC +10% (equivalent to 187…264VAC)
Up to software revision 101:
115VAC, 230VAC, tolerance: +10% / -15% depending on device version ( section 13 "How to order" on page 66)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Heatsealing band type and temperature range
Several different ranges can be selected on the controller in the Configuration menu:
Default: Temperature coefficient 1100ppm (Alloy A20), 0…300°C
Heatsealing band voltage (secondary voltage of impulse transformer)
12…42VAC
Max. load current (max. secondary current of impulse transformer) Terminals 5, 6, 7, 8
Two heatsealing bands:
One heatsealing band:
Min. load current
Up to SW revision 007:
SW revision 008 or higher:
Analog output (actual value) Terminals 10+11
0…10V DC, Imax = 5mA Equivalent to 0…300°C or 0…500°C Accuracy: ±1% add. 50mV
Isec max = 90A (per heatsealing band: Imax = 45A) Isec max = 70A
If only one heatsealing band is used, terminals 7+8 must be externally jumpered with a high current cable in order to
avoid malfunctions or damage to the controller.
!
Isec min = 30A Isec min = 20A
Motherboard and display terminal (with same serial number) are aligned on each other during production (before first delivery). When
using components with different serial numbers together the analogue output has higher tolerances.
!
START with contact Terminals 12+14
Switching threshold: 3.5VDC, Umax = 5VDC, Imax = 5mA
FOOT SWITCH with contact Terminals 12+13
Switching threshold: 3.5VDC, Umax = 5VDC, Imax = 5mA
Version 1
RES-430
Page 11
常见问题
关于Ropex品牌Ropex RES-430 Temperature Controller产品的常见问题。Imtek Engineering随时准备帮助您在United States采购Ropex的Ropex RES-430 Temperature Controller。
Imtek Engineering通过可信赖的供应渠道采购正品Ropex产品,并以具有竞争力的价格向United States客户提供。